WEP-2L. User manual
42
•
•
•
•
•
•
•
•
•
•
•
•
•
roCommunity
–
a password to read the parameters (by default:
public
);
rwCommunity
–
a password to configure (write) parameters (by default:
private
);
TrapSink
–
IP address or domain name of SNMPv1-trap message recipient in HOST [COMMUNITY [PORT]]
format;
Trap2Sink
– IP address or domain name of SNMPv2-trap message recipient in HOST [COMMUNITY [PORT]]
format;
InformSink
– IP address or domain name of Inform message recipient in HOST [COMMUNITY [PORT]]
format;
Sys Name –
device name;
Sys Contact
–
device vendor contact information;
Sys Location
–
device location information;
Trap community
–
password enclosed in traps (default value: trap).
The list of objects which are supported for reading and configuration via SNMP is given below:
eltexLtd.1.127.1 – monitoring access point parameters and connected client devices;
eltexLtd.1.127.3 – access point management (reboot).
where eltexLtd – 1.3.6.1.4.1.35265 is Eltex Enterprise ID.
To apply a new configuration and save setting to non-volatile memory, press «Apply». Press «Cancel» to discard
the changes.
5.8 The «External Services» menu
5.8.1 The «Captive Portal» submenu
The
«Captive Portal»
submenu is designed to enable and configure the APB service at the access point.
The APB service is used to provide portal roaming of clients between access points connected to the service.
Enable
– when checked, the point will connect to the APB service, the address of which is specified in the
«Roaming Service URL» field, to provide portal roaming of clients;
Roaming Service URL
– APB service address to support roaming in the portal authorization mode. Set in
format: "ws://<host>:<port>/apb/broadcast".