MES3000 Ethernet switch series
Privileged EXEC mode commands
Command line request appears as follows:
console#
Table 4.2 —Basic commands available in privileged EXEC mode
Command
Value/Default value
Action
unit mode {standalone |
stackable}
-
Defines the switch operation mode:
-
standalone
—switch can perform as a standalone device
-
stackable
—switch can be combined in a stack
The mode change takes effect after the switch is restarted.
unit renumber local afterreset
unit_id
unit_id: (1..8)/1
Specifies the device number
unit_id
to a local device (where the
command is executed). The command may be used in standalone
mode or stackable mode on the master device.
The device number change takes effect after the switch is
restarted.
unit renumber
current_id
after-reset
new_id
current_id: (1..8)
new_id: (1..8)
Specifies the
new_id
device number to the switch with the
current_id
number. This command may be used only on the
master device of the stack.
The device number change takes effect after this device is
restarted.
show unit
[
unit_id
]
unit_id: (1..8)
Shows information on devices in a stack.
If you enter this command without parameters, the brief
information will be shown for all devices in a stack.
If you specify
unit_id
, detailed information will be shown for the
specific device.
Example use of
show unit
command:
console#
show unit
1
Unit: 1
MAC address: a8:f9:4b:80:bf:40
Master: Enabled.
Product: MES-3124F 28-port Fiber 1G/10G Stackable Managed Switch.
Software: 02/05/2014
Uplink unit: 2
Downlink unit: 0
Status: master
Active image: image-2
Selected for next boot: image-2
Topology is Chain
Stack image auto synchronization is enabled
Unit Mode After Reset: stacking
Unit Num After Reset: 1
Table 4.3—Description of 'show unit' command execution results
Field
Description
Unit:
Identifier of the selected device
MAC address:
Switch MAC address
Master:
Permission to become the master device in a stack.
Product:
Switch model description.
Uplink unit:
Identifier of a switch connected to the uplink port (for MES3124—XG3, for
MES3116,3108—XG1)
Downlink unit:
Identifier of a switch connected to the downlink port (for MES3124—XG4, for
MES3116,3108—XG2)
Status:
The current role of the switch in a stack
Active image:
Active firmware image
Selected for next boot:
Firmware image that will become active after restart