Specifications
13.1
Common transmitter specification
RF specification EN300-220
RF power 10mW
Environment specification:
Compliant to EN300-220 -10 to +55ºC
Actual -30 to +65ºC
Humidity 100% non condensing
Environmental rating IP40
Dimensions (footprint) 78 x 41mm
Battery endurance up to 5 years (interval set to 5 minutes)
Transmission interval range
(less for GL-70 and GS40 series)
1 sec to 4 hours
Indicator (red LED) transmit active/on/off
Control switch (concealed) test mode / hibernate
Antenna socket SMA
13.2
Individual transmitter specifications
Models
Sensors
Range
Resolution
Accuracy
GC04/GD
04
1 x external thermistor temperature
-40 to
+70ºC
0.1ºC
±0.2ºC (-15
to +40ºC)
0.2ºC
±0.4ºC (-29
to +65ºC)
0.3ºC
±0.6ºC (-36
to +70ºC)
0.4ºC
±0.8ºC (-40
to -36ºC)
GC06/GD
06
built-in thermistor temperature
As GC04
GC10/GD
10
built-in temperature (digital sensor)
-30 to 65ºC
0.1ºC
±0.4ºC (+5 to
+40ºC)
±1.0ºC (-20
to +65ºC)
±1.5ºC (-
30ºC)
built-in RH
0-100%
0.1%
±2% (10 to
90%RH)
±4% (0 to
100%RH)
GD11
built-in temperature and RH
As GC10
external thermistor temperature
As GC04
GD13E
external RH (RHT10E)
0-100%
0.1%
±2% (10 to
90%RH)