S Y S T E M
C O N T R O L
_________________________________________________________________________________
GsmAlarm-500
Software ver. 1.15
-
47-
8.1.3.
[MEM] KEY – ALARM MEMORY DISPLAY
If an alarm has occurred on a zone, the respective zone LED will flash, the [MEM] key will light up, and
the zones will be stored in memory. Memory indication mode is activated by pressing [MEM] key
([MEM] starts to flash). Alight keys indicate which zone had been triggered.
Memory is erased automatically when armed mode is activated or by pressing [CLEAR] key when
memory indication mode is active.
If K32LCD KEYPAD is used, after pressing [MEM] and further [BYP], it can be seen what were the last
alarm events. It is shown in the LCD display when and what zone was activated. 128 last events are
stored in the memory of system.
8.1.4.
[BYP] KEY – BYPASS PROGRAMMING
A bypassed zone will not cause an alarm. If a zone is bypassed the panel may be armed (Ready light will
be on) even if the zone is open. Use zone bypassing when access is needed to part of the protected area.
Also, damaged wiring or contacts on a zone may be temporarily bypassed until repairs can be made so
that the panel can be armed. To bypass zones, press [BYP] key and enter 4 or 6 digit user access code.
[BYP] key starts to flash. Zone can be bypassed by pressing key, indicating certain zone number.
Constantly alight key indicates of certain zone as bypassed. To activate zone, press key, indicating certain
zone number one more time. Press [CLEAR] key to turn off BYPASS programming mode. System
memorizes bypassed zones. Constantly alight key [BYP] indicates, there are some bypassed zones in
system memory. BYPASS memory is erased automatically after disarming the system. If bypassed zone
is operating in 24-hour mode, BYPASS mode is not turned off automatically. In this case BYPASS mode
can be switched off only by keypad or in a remote way, while calling and entering corresponding code or
by sending SMS message.
8.1.5.
[CLEAR] KEY
Use the [CLEAR] key to clear mistakes when entering user code (etc.) or to return to main keypad mode.
8.1.6.
[ENTER] KEY
Use the [ENTER] key to activate system parameter programming mode.
8.1.7.
“
~
”
AC MAINS INDICATOR
This indicator is not alight when there is no 230 VAC power supply voltage and system is powered by
backup battery only.
8.1.8.
“StayD” (STATUS) INDICATOR
Indicator is on when all zones are closed and system is ready to be armed.
8.1.9.
“OFF” INDICATOR
Indicator is on if the system is disarmed.