P R O G R A M M I N G
_________________________________________________________________________________
GsmAlarm-500
Software ver. 1.15
-
29-
5.7.
PROGRAMMING THE SYSTEM USING THE KEYPAD
All system parameters, except for user phone numbers and names of zones and outputs, are
programmable using keypad. User numbers are programmed only by sending SMS message or by
method described in Ch. 5.2.1, names – SMS message or via GAprog program.
To program system parameters:
•
Press the [ENTER] key.
•
Enter your system installer code (default code is 0000 or 000000). The lights ARM and
STAY will flash, programming mode is activated.
•
Select the parameter by entering a 3-digit address. The lights ARM and STAY will lit
constantly.
•
Enter a new 2-digit parameter.
•
Press the [CLEAR] key to exit the programming mode.
All parameters and addresses of the parameters are provided in the table. Please see Chapters 5.7.1
– 5.7.29 for more detailed information.
* parameters if programming by SMS message.
Address
Parameter description
SMS
parameters*
000
Installer access code (4 or 6 digits).
-
001-020
User access codes (4 or 6 digits).
-
021
CONTACT ID user identification number.
CIDACC
031-050
User code function.
-
100
Exit delay.
T (S01)
101-115
Zone operating mode: entry delay or triggering temperature.
T (Z01-Z15)
133
Delay time of report SMS about the failure of main power supply.
G (S01)
141-144
Output operating mode: operating time.
T (C01-C04)
151-165
Zone response time
-
171-176
Temperature correction.
-
201-215
Zone Z1-Z15 operating mode: triggering conditions.
A (Z01-Z15)
233
Mode of data transfer to alarm monitoring station.
H (S01)
234
User code length (4 or 6 digits).
-
235
Exit delay audible indication.
-
236
Dividing the system into two partitions. 24 hour tamper supervision.
P (S01)
237
SMS structure and SMS password functionality.
L (S01)
238
GSM JAMMING notification.
J (S01)
239
Backup battery monitoring.
-
240
StayD indication.
-
241-255
Input operating mode: alarm state after input triggering.
M (Z01-Z15)
273
Informing users about arming and disarming.
E (S01)
274
Responding to unrecognized caller ID and number of calls in the case of
alarm.
F (S01)
275
Informing users when STAY or SLEEP mode switching ON.
276
Informing users when STAY or SLEEP mode switching OFF.
281-295
Zone operating mode: dividing into the partitions and partial protection
modes STAY and SLEEP.
P (Z01-Z15)
320
Output operating mode: inverted / not inverted.
V ( C01-C04)
321-324
Output operating mode.
M (C01-C04)
326
Output operating time units: seconds / minutes
V ( C01-C04)
331-345
Pulse counting mode.
I (Z01-Z15)
401-420
Timer events.
STIMER
900
Time and date programming.
SCLOCK