background image

 
 

 

_________________________________________________________________________________ 
GsmAlarm-500                                                  

                                                          

Software ver. 1.15 

 

GsmAlarm-500 (V1.15) 

 

 

GSM Alarm and Remote Control System 

 
 
 

 

 
FEATURES 

 

 

6 inputs.  

 

Up to 15 protection zones. 

 

3 programmable low current o 1 high current relay output. 

 

5 users are notified. 

 

20 programmable keypad access codes or iButton  keys. 

 

Possibility to transfer data to alarm monitoring station via GPRS channel by SIA DC-09 IP 

protocol.  AES128 encryption. 

 

Possibility to connect to SmartCloud server. Monitoring and control of the system can be 

performed from any computer or smart phone using a standard web browser. 

 

Possibility to send information to alarm monitoring station using the Contact ID protocol 

through GSM voice call. 

 

Remote control using mobile phone keypad (through DTMF tones). 

 

GSM JAMMING detection. 

 

24 hour timer. 

 

Two partial protection modes (STAY and SLEEP). 

 

Possibility to divide the system into two independent partitions. 

 

Possibility to connect up to 6 temperature sensors for temperature measurement

 

Possibility to connect up to 4 keypads. 

 

Info-carrying SMS showing state of each sensor, power supply voltage, GSM signal 
strength.
 

 

Programming and firmware upgrade via USB connection. 

 

Remote programming over GPRS. 

 

Integrated quad-band GSM module. 

 

Wide operating temperature range: -35 … +65ºC.

Содержание GsmAlarm-500

Страница 1: ...e performed from any computer or smart phone using a standard web browser Possibility to send information to alarm monitoring station using the Contact ID protocol through GSM voice call Remote contro...

Страница 2: ...nsors 12 5 Programming 13 5 1 General Programming Instructions 13 5 2 User and Alarm Monitoring Station numbers 13 5 2 1 Programming with Standard Mobile Phone 14 5 2 2 Programming with SMS 14 5 3 Pro...

Страница 3: ...g Calls and Number of Calls in Alarm State 35 5 7 15 Parameter G Delay Time of Report SMS about the Power Supply Failure 36 5 7 16 Parameter H Data Transfer to the Alarm Monitoring Station 36 5 7 17 P...

Страница 4: ...dicator 47 8 1 10 ARM SLEEP and STAY Indicators 48 8 2 Regular Arming 48 8 3 Stay Sleep arming 48 8 4 Disarming Deactivating an Alarm 49 8 5 Panic Alarms 49 8 6 Control of Separate Partitions 49 8 7 P...

Страница 5: ...nside installation room with automatic 2 pole circuit breaker capable of disconnecting circuit in the event of short circuit or over current Open circuit breaker must have a gap between connections of...

Страница 6: ...ant to moisture chemical materials or mechanical damage Don t attempt to personally repair the system System label is on the top side of the device This symbol on the product or on its packaging means...

Страница 7: ...mine protected unit state system mode etc The system is controlled by iButton also known as DALLAS keys Several control functions can be assigned to each key Example a user can activate a protection m...

Страница 8: ...ors KTY81 110 PHILIPS The zones are designed to work with End of Line EOL resistors of 2 2k and 4 7k in ATZ mode see Ch 4 2 4 The system becomes triggered both when the input circuit is broken as well...

Страница 9: ...Ch 5 3 2 1 Equivalent diagram of C output 2 5 BELL SIREN CONNECTION TERMINALS K1 and K2 These terminals are relay contacts of the programmable output C4 K1 and K2 are used to connect audio siren or ex...

Страница 10: ...is being sent Blinks 5 times short break after Very good signal Blinks 4 times short break after Good signal Blinks 3 times short break after Satisfactory connection Blinks 2 times short break after...

Страница 11: ...in metal housing 7TRP20 as recommended Housing fixture holes 4x5mm SAUGIKLIS Metal housing 7 TRP20 RED BLUE POWER SUPPLY TRANSFORMER T 0 16A LSTEN 60950 TRP 20 01 BACKUP BATTERY AC 12V 1 3Ah CT1 3 12...

Страница 12: ...status LED indicator woks in sync with the MODE indicator see Ch 3 2 The state of this indicator allows identification of the alarm system status and verification of closure of all protected zones be...

Страница 13: ...BLUE 1k GREEN YELLOW BLACK BLUE Keypad No 2 RED 1k Keypad zone 2 Power supply for motion or fire detectors K1 K2 Siren 4 7k 2 wire smoke detector EA318 2 AC 230V 0 16A Fuse 5 2 4 2 2 SYSTEM WITH iBUTT...

Страница 14: ...ply transformer and the backup battery are connected according to the wiring diagram of the premise security system see Ch 4 1 The gate control system operating output C4 is connected to terminals K1...

Страница 15: ...s 6 inputs Z1 Z6 corresponding to the zone numbers Z01 Z06 If 6 zones are sufficient for protection of the object the wiring diagrams 1 2 3 or 4 may be deployed Load resistors are mounted in the housi...

Страница 16: ...be programmed only in 0 99 C range The temperature difference at which triggered zone returns to primary state hysteresis complies with the parameter I see Ch 5 3 1 In temperature measurement mode in...

Страница 17: ...block of GsmAlarm 500 device The parameters of the system can be programmed by sending SMS message see Ch 5 3 or by using Paradox keypad see Ch 5 7 It is recommended to change the SMS password at the...

Страница 18: ...station Important It s important to note that while programming SIM card memory should be active not phone memory Otherwise the user number will be recorded in the mobile phone memory used for program...

Страница 19: ...to receive SMS with programmed numbers ALRNR1 ALRNR5 send GsmAlarm 500 the following SMS A A A A A A A A N R I N F O Extra user numbers only for gate control are programmed by sending the following SM...

Страница 20: ...d output operating modes delay times and names can be programmed with the help of SMS First it is recommended to receive SMS with programmed parameters and then to send the same SMS with corrected par...

Страница 21: ...onds Minimal time 10 seconds 1 maximal time 90 seconds 9 The factory preset time 20 seconds If N 0 or N 1 the pulse counting mode is switched off In temperature measuring mode parameter I complies hys...

Страница 22: ...ired if tamper recognition is on see Ch 5 3 1 3 4 4 Follow zone 6 2 wire smoke detector connected to the PGM output C3 1 5 5 Double acting delay zone 7 ATZ mode with tamper recognition Triggers when c...

Страница 23: ...n the zone is restored contacts return to initial state the system does not call and does not turn on the siren In this case users only receives an SMS message if SMS message sending is activated see...

Страница 24: ...ystem parameters send GsmAlarm 500 the following SMS A A A A A A A A C P A R A M Receiving the message is confirmed by blinking of indicator MODE SMS with current system parameters is being sent AAAAA...

Страница 25: ...onset time J02 detection of GSM jamming signal activates the siren J03 operates as the functions J01 and J02 K00 the method of system control K00 the system is controlled by a PARADOX keypad K01 the s...

Страница 26: ...hort call number coincides with programmed numbers M06 Siren mode M07 Siren mode with audible confirmation After arming one short audible beep is heard After disarming two short audible beeps are hear...

Страница 27: ...ren mode the output operating time can be programmed only in minutes 5 3 2 3 CONFIGURATION OF THE GATE CONTROL MODE Connect the system after the wiring diagram presented in Chapter 4 2 3 The message A...

Страница 28: ...f a call is received from unknown caller user ALRNR1 will receive a SMS with caller s number 1 1 After alarm triggering users are called once If calling from user s number after 3 4 calls the system w...

Страница 29: ...nt to all users ALARNR1 ALARNR5 Manufacturer programmed value L32 Important To activate several functions the total of numbers should be used Example To activate all three functions the digit X should...

Страница 30: ...year month day GsmAlarm 500 sends back SMS with programmed system time to the specific user 5 3 5 PROGRAMMING 24 HOUR TIMER Timer function can activate or deactivate the programmable output arm or dis...

Страница 31: ...tput C2 33 Activates output C3 30 Deactivates output C3 44 Activates output C4 K1 K2 40 Deactivates output C4 K1 K2 77 Requests to send SMS message with information about output state 80 Disarms the f...

Страница 32: ...sage is sent to GsmAlarm 500 to receive an SMS message with the user names A A A A A A A A U P A R A M GsmAlarm 500 sends 3 messages with user names to the user AAAAAAAA U01 User1 U02 User2 U03 User3...

Страница 33: ...15 Zone operating mode entry delay or triggering temperature T Z01 Z15 133 Delay time of report SMS about the failure of main power supply G S01 141 144 Output operating mode operating time T C01 C04...

Страница 34: ...ts ARM and STAY will lit constantly Enter a new 4 or 6 digit access code To delete an Access Code Press the ENTER key Enter your system installer code default code is 0000 or 000000 Select a user by e...

Страница 35: ...r access code functionality 035 5 user access code functionality 036 6 user access code functionality 037 7 user access code functionality 038 8 user access code functionality 039 9 user access code f...

Страница 36: ...riggered It is described in detail in Chapter 5 3 1 2 Manufacturer programmed values for all zones 70 Address Parameter 101 Zone Z1 T parameter 102 Zone Z2 T parameter 103 Zone Z3 T parameter 104 Zone...

Страница 37: ...al time 10 seconds 1 maximal time 90 seconds 9 If Ni 0 or Ni 1 the pulse counting mode is switched off In temperature measuring mode this parameter comply temperature difference at which triggered zon...

Страница 38: ...utput C3 144 Operation time of output C4 K1 K2 In siren mode operation time is in minutes in all other modes in seconds or in minutes Manufacturer programmed time C1 00 sec C2 05 sec C3 00 sec C4 K1 K...

Страница 39: ...ts the number to be entered is 15 1 2 4 8 5 7 13 PARAMETER E THE WAY USER IS INFORMED ABOUT ARMING AND DISARMING Parameter E is described in detail in Chapter 5 3 2 2 Manufacturer programmed value 20...

Страница 40: ...SYSTEM RESPONSE TO INTENTIONAL GSM JAMMING Parameter J defines the system response to intentional GSM jamming Manufacturer programmed value 01 5 7 18 PARAMETER L SMS STRUCTURE AND SMS PASSWORD FUNCTIO...

Страница 41: ...r K32LCD keypad is used keypad zone is selected by pressing two digits For example if you want to assign zone 16 to the keypad zone press 1 and 6 If you want to assign zone 3 press 0 and 3 Keypad zone...

Страница 42: ...cating event number The lights ARM and STAY will lit constantly Enter 6 digit event instruction and event time First two digits event instruction where following four timer activation time E g for out...

Страница 43: ...ws programming deletion and assigning of iButton keys to a specific user or programmable output and setting up of key control functions The GSM alarm configuration tool is downloadable from the websit...

Страница 44: ...module it is recommended to verify access point settings Send the following SMS message to GsmAlarm 500 or if SMS password is deactivated The massage returned to the user by GsmAlarm 500 contains the...

Страница 45: ...RS enter the port number click the button Wait and wait for the GSM module to connect to the computer The GSM module retries connecting to the specified IP address every 30 seconds The computer IP add...

Страница 46: ...e5 205 A30 245 M70 285 P10 335 I02 105 T00 Z6 Zone6 206 A30 246 M70 286 P10 336 I02 106 T00 Z7 Zone7 207 A52 247 M70 287 P10 337 I02 107 T00 Z8 Zone8 208 A00 248 M70 288 P10 338 I02 108 T00 Z9 Zone9 2...

Страница 47: ...he LED of security system keypad will indicate a connection problem fault Once the system will get a response from the monitoring station the LED indicator will go off in this case a test message will...

Страница 48: ...C 1 2 3 4 AAAAAAAA SMS password CIDACC programming command 1234 four digit user account number Important a no characters or spaces can be used before the password b no spaces are allowed before and a...

Страница 49: ...receive information about the object only after sending appropriate SMS message or after calling to GsmAlarm 500 number and entering appropriate DTMF code If H value is H11 or H12 GsmAlarm 500 is oper...

Страница 50: ...s case Z11 zone is corresponded by key 1 Z12 key 2 Z15 key 5 Extended indication mode is switched off after pressing once again or after pressing CLEAR 8 1 2 TBL KEY TROUBLE DISPLAY If key TBL illumin...

Страница 51: ...made so that the panel can be armed To bypass zones press BYP key and enter 4 or 6 digit user access code BYP key starts to flash Zone can be bypassed by pressing key indicating certain zone number C...

Страница 52: ...tly User receives confirmation short call or SMS message depends on system configuration see Ch 5 3 2 2 If system is divided into two partitions only one partition or both partitions at once can be ar...

Страница 53: ...vated or deactivated together 8 7 PROGRAMMABLE OUTPUT CONTROL The programmable output PGM on the GsmAlarm 500 can be made to activate by a command from the keypad This output can be used for operating...

Страница 54: ...f system is divided into two partitions names of protected objects partitions can be seen in the SMS message OBJECT 1 SYSTEM ARMED SLEEP MODE USER1 OBJECT 2 SYSTEM DISARMED USER2 System can be configu...

Страница 55: ...s armed or disarmed While answering user hears what is happening in the premises and also can control system by by entering 2 digit codes using his phone keypad For example after entering code 99 the...

Страница 56: ...as capability to detect intentional jamming of GSM If the detection function is on see Ch 5 3 2 or 5 7 17 the siren is activated upon detection of the jamming signal and the user is informed thereof b...

Страница 57: ...ivates output C1 10 Deactivates output C1 22 Activates output C2 20 Deactivates output C2 33 Activates output C3 30 Deactivates output C3 44 Activates output C4 K1 K2 40 Deactivates output C4 K1 K2 77...

Страница 58: ...ontrolled by this number for gate or fence control ADDNR C2 Additional user number programming instruction Only the output C2 is controlled by this number for gate or fence control ADDNR C3 Additional...

Страница 59: ...PRS settings MSTID User ID programming for monitoring station server GPRS channel MSTIP IP address programming for monitoring station server MSTPR Port programming for monitoring station server SCON S...

Страница 60: ...blank Save data into the device Create an account on web page sc eltech lt Once you have an account register one or more GsmAlarm devices Create your own device name Device identification number and...

Страница 61: ...on purpose mechanical chemical electric damage and in other cases that are not related with GsmAlarm 500 manufacturing defects are seen If security system is not operating properly or breaks down for...

Страница 62: ...tive state Closed contacts Non active state Open contacts PROGRAMMABLE OUTPUTS C1 C2 C3 Output type Open collector Maximum current 150 mA max Output active Connected to GND Output non active Open cont...

Страница 63: ...MOUTING HOLES _________________________________________________________________________________ GsmAlarm 500 Software ver 1 15 59...