P R O G R A M M I N G
_________________________________________________________________________________
GsmAlarm-420 Software ver. 1.05
- 17 -
5.3.2.1.
OUTPUT C1, C2 AND BELL OPERATION MODE
Output
mode
Explanation of operation
M00
Not in use.
M01
Output controlled by DTMF or SMS instructions.
If zero operation time is programmed (T00), output is activated/deactivated and
remains in the same state after receiving DTMF or SMS instruction.
If not zero operation time is programmed, after receiving DTMF or SMS
instruction, output is activated, it deactivates automatically after expiration of the
programmed time.
M02
LED mode. Output is in operation together with MODE indicator.
M03
Output is activated, when system is armed. Open contact, when system is disarmed.
M04
Control by short call without number recognition function. Output is activated with
a call from any number. If zero operation time is programmed (T00), output state
changes after a call and remains unchanged till the next short call.
If not zero operation time is programmed, after receiving short call instruction
output is activated, it deactivates automatically after expiration of the programmed
period.
M05
Control by short call with number recognition function (gate control mode). This
mode operates analogue to M04, thus it is activated only if short call number
coincides with programmed numbers.
M06
Siren mode. Valid only for output BELL (C3).
M07
Siren mode with audible confirmation. After arming, one short audible sound is
heard. After disarming, two short audible sounds are heard. Valid only for output
BELL (C3).
M08
Miniature siren (buzzer) mode (see Ch. 7.1).
M09
Output is activated if GSM connection is absent for over 30 seconds in the
protection mode. After connection is re-established or protection mode deactivated,
the output is also deactivated. When the connection is normal, the output operates
in the same way as in mode M01.
Outputs are controllable in armed and disarmed modes.
5.3.2.2.
PARAMETER E : INFORMING USER ABOUT ARMING AND DISARMING
System response to switching the
armed mode ON
E
XY
System response to switching
the armed mode OFF
X
Y
All functions below are
deactivated.
0
0
All functions below are
deactivated.
User is informed by SMS.
1
1
User is informed by SMS.
User is informed with a short call.
2
2
User is informed with a short
call.
-
-
4
If during the period of one
minute after disarming by call
no change in the input state is
found, system automatically
returns to “armed” mode.