P R O G R A M M I N G
_________________________________________________________________________________
GsmAlarm-420 Software ver. 1.05
- 15 -
5.3.1.1.
PARAMETER M
Alarm state after input triggering
M
XY
Input operation mode
X
Y
All functions, described below, are
deactivated.
0
0
Input with programmable delay
time. *
Siren is operating.
1
1
24 hour input. **
Calling.
2
2
Fire sensor connection input ***
Siren is operating and calling.
3
3
ON/OFF zone. ****
Sending SMS message.
4
-
Follow zone. *****
Siren is operating and sending SMS
message.
5
-
-
Calling and sending SMS message.
6
-
-
Siren is operating, calling and
sending SMS message.
7
-
-
* Input with programmable delay time. After relevant zone is being triggered, the system will switch
alarm on only if armed mode is active, after expiration of the given delay time T.
** 24 hour input. After relevant zone is being triggered, the system switches alarm on with no respect
to armed mode (ON/OFF), siren operates constantly, delay time is ignored.
*** Fire zone mode. 24 hour input, siren is operating with interruptions.
**** Zone ON/OFF. Mode designated to turn armed mode on/off .
***** Follow zone. After violation of this zone alarm goes on immediately, if other zone with delay
isn‘t violated. If firstly zone with delay is violated (for example, doors are opened), “follow” zone
receives delay time of earlier violated zone. It is recommended to apply this mode to motion sensor
zone, if sensor is installed before the entry doors to the room.
5.3.1.2.
PARAMETER A
Input triggering conditions
A
XY
Users, getting information about
zone violation
X
Y
Zero-one mode, active level: low
(GND).
0
0
All (ALRNR1-ALRNR5).
Zero-one mode, active level: high
(+12V or open contact).
1
1
Only user ALRNR1.
Loaded input mode, 2,2k
Ω
load
required.
2
2
Only user ALRNR2.
-
-
3
Only user ALRNR3.
-
-
4
Only user ALRNR4.
-
-
5
Only user ALRNR5.
-
-
6
Users ALRNR1 and ALRNR2.
-
-
7
Users ALRNR1, ALRNR2 and
ALRNR3.
-
-
8
Users ALRNR1, ALRNR2,
ALRNR3 and ALRNR4.