P R O G R A M M I N G  

 

_________________________________________________________________________________   

GsmAlarm-420                                                                                                           Software ver. 1.05 
 

- 11 -

 

5.

 

PROGRAMMING 

 
 

GsmAlarm-420 parameters can be divided into two groups. First group – user phone numbers which 
are stored in SIM card memory. User phone numbers can be programmed by using standard mobile 
phone  of  any  type  (see  Ch.  5.2.1)  or  remotely,  sending  SMS  message  with  the  phone  numbers  of 
users to GsmAlarm-420 (see Ch. 5.2.2). 
Second  group  –  parameters,  defining  system  operation  algorithms,  names  of  protected  zones  and 
programmable outputs.  These parameters are stored in the memory block of GsmAlarm-420 device. 
The  parameters  of  the  system  can  be  programmed  by  sending  SMS  message  (see  Ch.  5.3).  It  is 
recommended to change the SMS password at the end of programming (see Ch. 5.4)    
 
If GsmAlarm-420 is used for protection, five user numbers can be programmed: ALRNR1, ALRNR2, 
ALRNR3, ALRNR4
 and ALRNR5. These users can arm/ disarm the system, calls will be directed and 
SMS  messages  will  be  sent  to  these  users.  If  only  one  user  exists,  he  must  be  programmed  under 
ALRNR1.  GsmAlarm-420  will  send  SMS  messages  to  this  specific  user  in  case  of  main  power 
supply loss or if an unknown number calls the system.  If armed mode is turned on or off by turning 
the switch ON/OFF GsmAlarm-420 dials and SMS messages are also directed to the first user. Other 
four user numbers are not obligatory.  
In  case  GsmAlarm-420  is  used  only  for  gate  control  it  is  not  necessary  to  program  ALRNR1- 
ALRNR5. 
Up to 250 user numbers, with the possibility to control the outputs C1, C2, and BELL with 
a  short call,  can be  programmed  in  this case.  Any  name  can  be  ascribed to  user.    Output  operation 
mode has to be M04 or M05 (see Ch. 5.3.2.1).    
After programming of user numbers - programmed system parameters, names of inputs and outputs 
(see Ch. 5.3). 
 
 
5.1.

 

USER NUMBER PROGRAMMING WITH STANDARD MOBILE PHONE 

 
Insert  SIM  card  into  a  standard  mobile  phone.  Enter  user  name  into  SIM  card  number  book  using 
capital letters e.g. ALRNR1 and corresponding phone number. We recommend enter the number with 
international code. (E.g. +370....) 
If GsmAlarm-420 is used for gate control, number of extra user numbers can be as large as fits into 
the SIM card (up to 250). Any name can be ascribed to user.  

 

Important: 
It‘s  important  to  note  that  while  programming  SIM  card  memory  should  be  active  (not  phone 
memory!).  Otherwise  the  user  number  will  be  recorded  in  the  mobile  phone  memory  used  for 
programming and the SIM card will remain empty. 

 

After having programmed all user numbers, it is recommended to check whether SMS service centre 
number  is  programmed.  Simplest  way  to  check:  send  any  SMS  from  the  phone  used  for 
programming. If it is sent successfully we can be sure that SMS centre number has been programmed 
correctly. Otherwise, program SMS centre number following the mobile phone’s user manual. SMS 
centre number can be learnt from GSM service provider. 
After completion of programming and checking whether SIM card PIN code request is switched off, 
take the SIM card off from the mobile phone. 
 
 
 
 
 
 
 

Содержание GsmAlarm-420

Страница 1: ...r connection 3 programmable outputs for remote control Option to switch the protection mode on off by short free call 5 users are informed on the protected unit 250 users able to control the gate or electromagnetic lock by short free call Info carrying SMS on the state of each sensor number of triggers system mains voltage GSM signal strength Option to connect siren Option to connect external mic ...

Страница 2: ...5 Programming 11 5 1 User Number Programming with Standard Mobile Phone 11 5 2 User Number Programming with SMS 12 5 3 System Parameter Programming with SMS 14 5 3 1 Protected Zones Z1 Z5 Parameter Programming 14 5 3 1 1 Parameter M 15 5 3 1 2 Parameter A 15 5 3 2 Programming of Output C1 C2 BELL and Common System Parameters E F T U 16 5 3 2 1 Output C1 C2 and BELL Operation Mode 17 5 3 2 2 Parame...

Страница 3: ...tisfy the safety requirements of LST EN 60950 1 standard External power supply can be connected to AC mains only inside installation room with automatic 2 pole circuit breaker capable of disconnecting circuit in the event of short circuit or over current Open circuit breaker must have a gap between connections of more than 3mm and the disconnection current 5A Only a qualified specialist possessing...

Страница 4: ...Don t attempt to personally repair the system System label is on the bottom side of the device This symbol on the product or on its packaging means that your electrical and electronic equipment should be disposed at the end of life separately from your household wastes There are separate collection systems for recycling in EU For more information please contact the local authority or the dealer wh...

Страница 5: ...e system can indicate entrance exit with an audio signal if the miniature sound signalization element is connected to system A user will receive an SMS message if GSM connection was lost for over 30 seconds The message is sent only when the protection mode is turned on The device suites perfectly for remote control of automated gates fences and electromagnetic door locks In order to open a gate a ...

Страница 6: ...mode or in a zero one mode see Ch 5 3 1 2 The loaded input mode is recommended to be used for protection of premises In this case all the inputs have to be loaded with 2 2kΩ resistors The system becomes triggered both when the monitored input circuit is broken as well as when it is short circuited In the second case the system is triggered after breaking or short circuiting of the monitored input ...

Страница 7: ...3 2 1 C1 C4 equivalent diagram 2 4 OUTPUT BELL The BELL output is used to connect audio siren or extra commutated device see Ch 4 1 and 4 2 Commutated current may reach 0 6 A max Equivalent diagram of BELL OUTPUT 2 5 OUTPUT AUX AUX output is used to supply power external devices fire motion sensors and is short circuit protected This output has voltage 13 7 V or 6 8V depending on the system parame...

Страница 8: ...nnection Blinks once short break after Poor connection 3 2 Z1 Z4 INPUT STATUS INDICATOR Indicator state Explanation Out Input is not triggered Continuously On Input is triggered 3 3 MODE SYSTEM OPERATION MODE INDICATOR Indicator state Explanation Out No power supply or system failure Continuously On System is operative disarmed no zone sensors have been triggered On with short breaks System is ope...

Страница 9: ... 4 1 INSTRUCTION FOR PREMISES PROTECTION INSTALLATION System should be assembled in metal housing 7TRP20 as recommended Antenna is fixed on the top of outer side of metal housing Cable Hole Housing Fixture Holes 4 x 5 mm Metal Housing 7 TRP20 SIGNAL Z1 Z2 Z3 Z4 MODE ALARM G S M A L A R M 4 2 0 ANTENNA CONNECTOR RED BLUE RESERVE BATTERY AC 12V 1 2Ah CT1 2 12 SAUGIKLIS POWER SUPPLY TRANSFORMER T 0 1...

Страница 10: ...in a prominent place LED state indicates system operation mode status if all protected zones are closed before switching on armed mode User can arm disarm system with short call from user mobile phone parameter F should be F51 or F41 see Ch 5 3 2 3 Please note if trying to call the system in alarm state deactivation is not possible therefore it is recommended to use switch ON OFF designed for acti...

Страница 11: ...ic interference vehicle computer conditioner block of relays Avoid mounting system unit directly onto metal parts of vehicle to prevent accumulation of condensate in the system unit Mount GsmAlarm 420 in a way wire connectors are going from the bottom side of the unit Avoid placing wires adjacent to moving or hot parts of vehicle Reserve 6V battery must be accurately fixed close to GsmAlarm 420 de...

Страница 12: ...M card into GsmAlarm 420 SIM card holder turn system power on then wait till indicator SIGNAL will start to blink periodically and indicator MODE will be constantly alight In case SIGNAL is constantly alight check if SIM card s PIN code request is off and GSM antenna is connected GSM signal quality can be evaluated according the blinking frequency of SIGNAL indicator Connection is very good if it ...

Страница 13: ...s used only for gate control it is not necessary to program ALRNR1 ALRNR5 Up to 250 user numbers with the possibility to control the outputs C1 C2 and BELL with a short call can be programmed in this case Any name can be ascribed to user Output operation mode has to be M04 or M05 see Ch 5 3 2 1 After programming of user numbers programmed system parameters names of inputs and outputs see Ch 5 3 5 ...

Страница 14: ...after the colon c Spaces must follow the password and each phone number d It is recommended to enter user numbers with international code e g 123 It is not necessarily to send all user numbers E g in order to programme only the first user number send the following SMS A A A A A A A A A L R N R 1 3 7 0 6 1 2 3 4 5 6 7 8 9 Receipt and decrypting of the SMS by GsmAlarm 420 is confirmed by blink of in...

Страница 15: ...elete the extra user number send to GsmAlarm 420 the following message A A A A A A A A D E L N R 3 7 0 1 2 3 4 5 6 7 8 9 1 D E L N R 3 7 0 1 2 3 4 5 6 7 8 9 2 D E L N R 3 7 0 1 2 3 4 5 6 7 8 9 3 Specified numbers will be deleted and user receives the confirming SMS DELET 3701234567891 DELET 3701234567892 DELET 3701234567893 Up to 8 user numbers might be deleted with one SMS message In order to rec...

Страница 16: ...ith frequent blinking of MODE indicator and sends SMS message including input parameters Z1 Z5 Received message will look as follows AAAAAAAA Z1 M70T20A20 Door Z2 M70T00A20 Windows Z3 M70T00A20 Movement Z4 M71T00A20 Fire Z5 M02T00A20 OFF AAAAAAAA password Z1 protected zone input number M70 parameter defines system response to the violation of protected zone and which users are informed if certain ...

Страница 17: ...ystem switches alarm on with no respect to armed mode ON OFF siren operates constantly delay time is ignored Fire zone mode 24 hour input siren is operating with interruptions Zone ON OFF Mode designated to turn armed mode on off Follow zone After violation of this zone alarm goes on immediately if other zone with delay isn t violated If firstly zone with delay is violated for example doors are op...

Страница 18: ...inutes OutC1 OutC2 and Siren programmable output names A user can change the name under his own discretion Maximum number of name characters 10 PR E24F11L01T20U12 PR command for programming the common system parameters E24 the method to inform the user about activation deactivation of the armed mode The user can be informed by a short call or an SMS message see Ch 5 3 2 2 F11 system response to in...

Страница 19: ...on of the programmed period M05 Control by short call with number recognition function gate control mode This mode operates analogue to M04 thus it is activated only if short call number coincides with programmed numbers M06 Siren mode Valid only for output BELL C3 M07 Siren mode with audible confirmation After arming one short audible sound is heard After disarming two short audible sounds are he...

Страница 20: ...om ALRNR1 ALRNR5 thus the calling number is in SIM card gate control mode system answers the call after 3 4 signals and user can control the system with DTMF instructions Call automatically cancelled after 1 minute passes Note If several functions have to be operative sum of the numbers is used E g for all three X functions to be active X value must be 7 1 2 4 7 5 3 2 4 PARAMETER U RESERVE BATTETY...

Страница 21: ...arameters back to GsmAlarm 420 device Setup of user telephone numbers is described in Ch 5 5 1 5 2 and 7 3 ADDNR DELNR NRLIST Important Two identical telephone numbers cannot be programmed under different names The command NRLIST is used for review of the numbers see Ch 5 2 6 RESETTING SYSTEM PARAMETERS TO FACTORY DEFAULTS In order to return all system parameters back to default settings connect c...

Страница 22: ...ive SMS with programmed parameters c change parameter U12 into U06 and send the same SMS to GsmAlarm 420 Input parameters Input Name Parameter M Delay time T Parameter A Z1 Door M70 T00 sec A00 Z2 Bonnet M70 T00 sec A00 Z3 Boot M70 T00 sec A00 Z4 Shock M70 T00 sec A00 Z5 ON OFF M03 T00 sec A00 Output parameters Output Name Parameter M Operation time T C1 OutC1 M02 T05 sec C2 OutC2 M05 T05 sec C3 B...

Страница 23: ...s the call and in the case number is accepted switches the controlled device on or off GsmAlarm 420 responds to area violations only in armed mode except the case when the input operates in 24 hour mode Armed mode can be switched on only if all the areas are untriggered MODE LED is permanently on If MODE is on with short breaks some of the areas is active open window doors etc Armed mode can be sw...

Страница 24: ...ree tone confirmation signals If given instruction has already been executed earlier e g you want to switch on the commutator that is already ON user hears one tone confirming signal Speech mode can be activated in two ways user answers when GsmAlarm 420 calls or user calls and waits for GsmAlarm 420 to answer 3 4 call signals In this case relevant parameter F has to be programmed see Ch 5 3 2 3 o...

Страница 25: ...output C1 C2 and BELL parameters NRINFO Request to send SMS message with user numbers of security system ALRNR1 ALRNR5 PASSW SMS password change instruction ALRNR1 ALRNR2 ALRNR3 ALRNR4 ALRNR5 System users number programming instructions ADDNR Gate control mode users number programming instructions DELNR Gate control mode users number erasing instructions NRLIST Request to send SMS message messages...

Страница 26: ...ufacturing date dated on security system identification label Warranty is not valid if system is reconstructed wrongly assembled used not on purpose mechanical chemical electric damage and in other cases that are not related with GsmAlarm 420 manufacturing defects are seen If security system is not operating properly or breaks down for guarantee or post guarantee service please contact company tha...

Страница 27: ...C 12V Output voltage in car protection mode DC 6V Maximum current 1 A max Short circuit protection triggering current 2 A max SIREN OUTPUT BELL C3 Maximum current 0 6 A max Output active siren is on Connected to GND Output non active siren is off Open contact PROGRAMMABLE OUTPUTS C1 C2 Maximum current 150 mA max Output active Connected to GND Output non active Open contact INPUTS Z1 Z5 Load resist...

Отзывы: