background image

 

 

ZAKŁAD PRODUKCJI URZĄDZEŃ ELEKTRONICZNYCH „ELSTER” Sp.J. 

Obłaczkowo 150,  62-300 Września,  Polska 

www.elster.w.com.pl                                    mail: [email protected] 

fax: +48 61 43 67 690                                    tel.: +48 61 43 

77 690

 

ROOM PANEL 

ROOMSTER II RTx 

USER’S MANUAL FOR ASSEMBLY AND HANDLING  

The  room  panel  ROOMSTER  was  designed  for  cooperation  with  the 

Expert PID Dynamic 4D regulators 

  and  chosen  models  of 

Luksus EKO  PID 

Dynamic 

regulators.  It  has  a  house  temperature  week  program  with  the  

exact  measurement  of  the  room  temperature  from  0,1

o

C.  Thanks  to  the 

built-in  communication  with  the  boiler  the  device  displays  information 
about  emergencies  and  measured  temperatures.  The  panel  has  its’  own 
memory for the user’s settings and in case of cooperation with the Expert 
regulator  it  automatically  synchronizes  the  actual  timing  from  the  boiler 
controller, without having to adjust it manually. 

I. Preparation for work. 

The  room  panel  ROOMSTER  RTx  connects  wirelessly  with  the  boiler 

temperature  regulator  through  radio  communication  module  attached  to 
the regulator. The radio communication module and the room panel com-
municate  on the  selected frequency channel.  The  default  settings  indicate 
operation on the 0 channel. When in the room there are more than 1 room 
panels  operation,  each  of  the  module-panel  pairs  must  communicate  on 
different frequency channel. In such case there is a necessity to change the 
default settings.  

1. Preparation of the communication module RTX. 

When the boiler temperature regulator, either Expert or Luksus, is in 

the built-in version, the communication module must be connected to the 
regulator  through  putting  the  XLR  plug  to  the  appropriate  socket  in  the 
sensor  panel  on  the  boiler.    In  other  cases  the  connection  must  be  made 
through connecting three-wire cable coming out of the module to the regu-
lator terminal or valve intended for connect the panel: 

Terminal designations: 

Yellow 

color 

Version 1 

Version 2 

brown 

Br 

white 

Bi 

green 

AUX +5V 

AUX +5V 

Содержание ROOMSTER II RTx

Страница 1: ...rk The room panel ROOMSTER RTx connects wirelessly with the boiler temperature regulator through radio communication module attached to the regulator The radio communication module and the room panel com municate on the selected frequency channel The default settings indicate operation on the 0 channel When in the room there are more than 1 room panels operation each of the module panel pairs must...

Страница 2: ...ood quality In case of replacing the batteries by NiCd rechargeable batteries of 1 2V voltage the panel will not work The panel is delivered to the client with no batteries included In or der to put in new batteries or change the discharged batteries one should take the back site of the panel off using a small screwdriver and put the batteries in accordance with the description attached to the hou...

Страница 3: ...ked by a rec tangle OFF means that the program is turned off designation of the active day temperature designation of the active night temperature when the program is turned off the screen does not display any of these elements wireless communication state blinking element means no commu nication after establishing communication the element lights con stantly and it does not light at all in the lo...

Страница 4: ...o the temperature programming screens moving to information screens increasing or decreasing the settings of the actually active temperature or changing the set value during other parameters edition III Rule of operation For regulation purposes the panel uses two temperature values of the temperatures set by the user Day temperature comfortable temperature it is simultaneously the set temperature ...

Страница 5: ... the program change the program change the day set temperaturę change the time one should touch the button from the main screen the user will be moved to the point 1 and the choosing actual program screen will be displayed and an icon will start to light If the button does not resond to a short touch it is caused by moving the processor into the battery saving mode In such case one should hold the...

Страница 6: ... week program s edition In order to make changes i the week program one should choose ini tially actual program like it was described in point 1 When the program is turned off OFF the program edition is skipped The screen looks as follows How to set Using the one should choose the actual icon for a given time or the view mode the screen will display the timing and a small cursor will blink in a su...

Страница 7: ... comfortable temperature The screen looks as follows The icon and C blink How to set Using the buttons and one should set the wanted temperature in increments of 0 1 C Touch the button the user will be moved to the point 4 or if the program is turned off to the point 5 4 Setting the night lowered temperature The screen looks as follows The icon and C blink ...

Страница 8: ...our and minute a suitable segment of the screen will be blinking Using the buttons and set the wanted value Touch the btton the user will be moved to the main screen V Additional information During communication with the valve module or the controller the room panel receives additional information from the external devices which might be displayed on the main screen when pushing sequentially the b...

Страница 9: ...nnel number for connection with the controller If instead of the content an C icon is displayed it means that currently this information is not available for example because of lack of the weather sensor the information about the external temperature will not be displayed VI Emergencies The room panel also displays information about errors caused during the system s operation Generally every error...

Страница 10: ...racy 0 5 C Dimensions 77x140x19 mm Weight of the device with the bat teries 220 g VIII Device installation The room panel ROOMSTER II might be put on the flat Surface using the tiltable stand placed in the back part of the panel or it might be hung on the wall using three dowels Both ways of fixing are illustrated in detail on the drawing on the next page In order to separate the stand from the ba...

Страница 11: ...11 ...

Страница 12: ...y the producer The device given to the complaint the warranty card and the proof of purchase or its copy must be sent by post to the producer s address The device should be exploited in dry conditions in the temperature higher than 0 o C The warranty will not be valid when the device is mechanically damaged is exploited in unsuitable conditions or when it was fixed by an unauthorized per son Warra...

Отзывы: