![Elster EM260 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/elster/em260/em260_manual_2396875008.webp)
Manual EM260
with Volume Corretor EK260
8 / 8
Betriebsanleitung-EM260-EK260_en_f.doc
13 Technical Data
•
Internal communication module (only one of the following possibilities is integrated into the
EM260):
– Standard analogue modem: V.32bis (14.4 kbps)
– GSM module: Dual-Band 900/1800 MHz
– GPRS-TSC module: Dual-Band 900/1800 MHz
– ISDN adapter: V.110, V.120, X.75, PPP, HDLC
– Ethernet-LAN adapter: 10base-T, 10Mbit/s.
– ELSTER-CL0 interface card
•
RS232 / V.24 interface to the end device (RxD, TxD, Gnd, DCD, DTR, RI), galvanically
separated, screw terminals for leads with cross section 0.5...1.5 mm
2
•
Power supply for EK2x0 and EK-88: output 8.5 VDC +/-5% / 50 mA, galvanically separated,
screw terminals for leads with cross section 0.5...1.5 mm
2
•
5 VDC outputs for interface component of LIS100 devices, only switched on during modem
connection (online status), screw terminal for lead with cross section 0.5...1.5 mm
2
•
Power
supply:
– 90...260 VAC, L, N, PE
– 18...30 VDC, +, -, PE
– screw terminal for lead with cross section 0.5...1.5 mm
2
•
Synthetic housing (standard ABS) with metallised surface inside, IP65 in accordance with
EN60529, EMV cable fitting for shielded cable, otherwise synthetic cable fittings
•
Ambient
temperature:
- with analogue modem ‘INSYS i-module-Modem’:
0 ... + 50 °C
- with ISDN adapter ‘TA+HUX’:
0 ... + 50 °C
- with GSM modem ‘Wavecom-Integra’:
-10 ...+ 60 °C
- with GPRS-TSC modem ‘Wavecom-Integra’:
-10 ...+ 60 °C
- with RS-232 plate:
-10 ...+ 60 °C
- with CL interface (CL0, passive):
-10 ...+ 60 °C
- with Ethernet card:
0 ...+ 50 °C
•
Ambient humidity: max. 93%, non condensating
•
Declaration of EU conformity
in accordance with the current version of the EMC-Directive
89/336/EEC:
The product ‘EM260’ conforms to the current versions of the following standards:
Emission EN 55011 Class B (for domestic and commercial applications)
Immunity EN 61326 (Electrical equipment for measurement, control and laboratory use)
EN 12405 (Volume correctors)
EN 55024 (IT equipment, data transmission devices)