1 Safety 

Instructions 

!

 

 

Please read these instructions carefully before assembling, installing or commissioning 
the EM260 to avoid any damage, dangers or problems. 

Assembly and installation should be carried out by qualified personnel ! 

 

!

 

 

The ‘AC’ version of the EM260 has a power supply of 90...260 V. Do not touch any live 
parts as this is extremely dangerous ! 

Shut off the power supply before carrying out any installation work and before opening the 
housing !  

Switch the power back on only after all of the work has been completed and the housing 
has been firmly closed! 

 

Other notes: 

)

 

When using a GSM modem, switch off the power on the EM260 before inserting or 
removing the SIM card!!! 

)

 

The PE connections in both the EM260 and the EK260 should be as short as possible 
and have as wide a cross-section as possible. 

)

 

When assembling the front cover, ensure that the flat-strip cable for connecting the LEDs 
integrated into the front transparent film is plugged into the 4x1 pin strip ST8! 

)

 

In the GSM modem, the SIM eject button is next to the SIM insert carriage on the right! 

 

2 Features 

  Modem for use with ELSTER LIS-100 and LIS-200 end devices 

  Internal TTL interface for one of the following communication modules: 

– Standard analogue modem 
– GSM module 
– GPRS-TSC module 
– ISDN adapter 
– Ethernet LAN adapter.  
– ELSTER-CL0 interface card 

  RS232 / V.24 interface to end device (RxD, TxD, Gnd, DCD, DTR, RI), galvanically separated 

  Power supply for EK2x0 and EK-88

 

 

  5 VDC outputs for interface component of LIS100 devices, only switched on during modem 

connection (online status) 

  EMC in accordance with standards EN55011 Class B, EN55024, EN61326 and EN12405 

(standard for volume correctors) 

  Operating status display: Power on (green LED), Ring and Online (yellow LED) 

  Apart from mains cable, all cables are already assembled exworks (Plug & Play): 

– Data cable 
– Power supply for end device  
– Communication cable (TAE, ISDN, Ethernet, GSM antenna)

.

 

 

Содержание EM260

Страница 1: ...ÅÆ EK260 3 4 WIRING OF EM260 S COMMUNICATION INTERFACE 3 5 SETTINGS OF THE INTERNAL SERIAL INTERFACE IN THE EK260 3 6 SETTING THE PARAMETERS FOR THE COMMUNICATION MODULE 4 7 REPLACEMENT OF COMMUNICATION MODULES 5 8 POWER SUPPLY 5 9 OPERATING STATUS DISPLAY 5 10 JUMPER 6 11 MODEM RESET 6 11 1 Modem Watchdog 6 11 2 Cyclical modem reset via output 4 of the EK260 6 12 OPERATING AN EM260 WITH INTEGRATE...

Страница 2: ...ble When assembling the front cover ensure that the flat strip cable for connecting the LEDs integrated into the front transparent film is plugged into the 4x1 pin strip ST8 In the GSM modem the SIM eject button is next to the SIM insert carriage on the right 2 Features Modem for use with ELSTER LIS 100 and LIS 200 end devices Internal TTL interface for one of the following communication modules S...

Страница 3: ...is delivered separately for additional installation beside an EK260 the internal serial interface of the EK260 must be set in accordance with the software version of the EK260 and with the type of communication module integrated in the EM260 The serial interface of the EK260 must be parameterised before the EM260 is connected to the EK260 and switched on For this purpose the parameter software Win...

Страница 4: ...le Then you can select the parameter file WPP which fits to your application communication module version of EK260 Example EM260 Analogue modem with EK260 V2 51 Æ EK260_2v5 EM260 int Analog Modem Insys _a WPP Before disconnecting the button Init modem should be pressed Interface Modem initialisation Æ after it is disconnected the EK260 sends the parameters to the communication module The parameter...

Страница 5: ... 90 260 VAC version 18 30 VDC version PE PE 9 Operating status display Green LED Power on Yellow LED Ring Online GSM status depending on which communication module Modem is integrated yellow Online LED has the following meanings Analogue Modem ISDN Ethernet LED status Meaning off no connection flashing briefly ringing signal on online data transfer NB when a CL interface is in use the Online LED i...

Страница 6: ...ined by time window 1 In EM260 with Wavecom adapter board starting from V1 2 a watchdog function refer to chapter 11 1 is implemented ex works The watchdog controls the modem function and resets it in the case of a failure The presence of the watchdog makes the cyclical modem reset via output 4 of the EK260 unnecessary Output 4 of the EK260 can still be used for call acceptance The modem reset fun...

Страница 7: ...ameter file to be used depends on the software version of the EK260 EK260_yvy Funktion Modem Reset täglich EM260_x WPP where yvy software version of the EK260 e g 2v5 and x latest file index For a cyclical modem reset output 4 of the EK260 must be connected to the modem reset input Æ Wiring instructions see below Wiring instructions for cyclical modem reset If a cyclical modem reset is to be carri...

Страница 8: ...l for lead with cross section 0 5 1 5 mm2 Power supply 90 260 VAC L N PE 18 30 VDC PE screw terminal for lead with cross section 0 5 1 5 mm2 Synthetic housing standard ABS with metallised surface inside IP65 in accordance with EN60529 EMV cable fitting for shielded cable otherwise synthetic cable fittings Ambient temperature with analogue modem INSYS i module Modem 0 50 C with ISDN adapter TA HUX ...