Volume Conversion Device EK260
Elster GmbH
57
ArCal Frozen values
Frz
Freeze
ArCal
is the entry address for the calibration archive which contains the two last
manually frozen data rows with measurements. Freezing is carried out with
Frz
.
The calibration archive is especially intended for operating point checks.
Each archive data row has the following entries, whereby the abbreviated
designations generally flash for counter increments ("
∆
..."):
↔
ABNo
Time
Vb
∆
Vb
Vm
∆
Vm
↔
To "Check"
Block
number
Storage
time-point
Volume at
base cond.
Counter
increment
Actual
volume
Counter
increment
↔
VbRp
∆
VbRp
VmRp
∆
VmRp p
T
↔
Repair
counter
Counter
increment
Repair
counter
Counter
increment
Press.
Temperature
↔
K
C
Qb
Qm
Check
↔
Gas law
dev. factor
Conversion
factor
Flow at
base
conditions
Actual flow Checksum
To "ABNo"
-
Display test
The display flashes to test all segments.