EnCal 3000 Quad– Hardware Manual
22/06/2017
34/52
4
Data Communication
4.1
Local TCP/IP Data Communication
The main Data Communication Port of the EnCal 3000 Quad is the TCP/IP port, although 2 serial ModBus
ports are also available (see next paragraph). The TCP/IP Port (Ethernet UTP 10 Base-T) is necessary for
connection with RGC 3000 (Windows based interface for configuration, diagnostics and report generation),
but is also used by preference for ModBus communication with Flow Computers, DCS systems, PLC and
other ModBus hosts, if they are able to handle ModBus TCP/IP. If not, ModBus serial to TCP/IP are easily
available nowadays. For existing systems the 2 serial ModBus ports can of course also be used.
The picture below shows a typical set-up:
fig. 4-1 Typical Data Communication Set-up for Ethernet Communication with the EnCal 3000