CMS200
Product Manual, Issue 6
www.nexo.com
Page 45
6.
PARAMETER REFERENCE
Operation parameters define the alarms, self-learning, lights management, and also the delay to saving and
the saving temperature disable.
The parameter values vary between different cooler types, cooler characteristics, operating environments,
brand requirements, and operational preferences.
Parameter settings are defined by customers and can be loaded and edited automatically, via the XML files,
or manually.
This section lists the full set of parameters relevant to the CMS200 controller, with their descriptions,
ranges and default values detailed for reference.
Firmware: Sub Zero Cooler
6.1
Parameters by function
Temperature
Celsius or Fahrenheit (CF)
Set point (SP) and Differential (dIF)
Saving set point (SSP), Saving differential (Sd) and Saving temperature disable (PEr)
Appliance sensor: calibration 1 (CA1 )
Operation
Saving restart (Sr)
Delay to saving mode (dS )
Freeze-up protection (dtt )
Compressor rest time (rt )
Defrost
Defrost interval (dE) and Defrost duration (dd)
Defrost termination temperature (dtd)
Defrost heater relay (dHr)
Defrost activation temperature (ddt)
Defrost method (dF)
Defrost termination flag (dtF)
Self-learning
Learning period (LP) and activity frequency (AF)
Display
Display (dIS ) and Display stability (d2)
Lights
Light delay (Ld) and Marketing mode (Ar)
Evaporator fan
Fan set point (FSP)
Fan cycle on (FCO) and Fan cycle off (FCF)
Alarms
Alarm delay (Ad)
Buzzer enable (b0 ) and Buzzer duration (b1)
Refrigeration system failure (Ct )
Condenser high temperature (Ht )
Voltage
management
Supply high (HI)
Supply low (L0)
Stock sensing
Shelf data enable (ShF)