background image

RF-MSG Issued 17.05.2010 The right to make technical alterations is reserved. Errors subject to correction. 

3

RF-MSG-PF 

Installation:  

Mounting 

Protection rating:  

IP 20 

Dimensions:  

approx. 38 x 47 x 29 (W x H x D, mm, plus flexible 

antenna) 

Weight:  

approx. 60 g 

Ambient temperature: 

 

Operation -20…+70 °C, Storage -55…+90°C 

Ambient air humidity:  

max. 95% rH, avoid condensation 

Operating voltage:  

230 V AC 

Input: 

Operating voltage (Mains L1/N/PE)  

Output:  

1 × Drive 230 V (Up/Down/L),potential-free,  

loadable with max. 4 A / 230 V AC 

Radio frequency:  

868.2 MHz 

 

Teaching the radio connection 

Please teach each RF-MSG separately! 

If several motor control units are going to be operated from one supply cable, it is an 

advantage to teach the RF-MSG before the installation. 

 

1.

 

Put the control unit/remote control into the teaching mode (observe the 

corresponding manual/data sheet). 

2.

 

Activate the RF-MSG voltage supply. The motor control unit learns a connection to 

the control unit/remote control on its own 3 seconds after the mains voltage is 

applied. 

Only one motor control unit can be recognised at a time.

 

3.

 

Note the feedback from the control unit (“Teaching completed”). 

 

If additional RF-MSGs are to be taught, repeat the teaching procedure.  

 

Содержание RF-MSG

Страница 1: ...ion 1 20 onwards Technical specifications and installation instructions Elsner Elektronik GmbH Steuerungs und Automatisierungstechnik Herdweg 7 D 75391 Gechingen Germany Phone 49 0 70 56 93 97 0 Fax 49 0 70 56 93 97 20 info elsner elektronik de www elsner elektronik de ...

Страница 2: ...al RF MSG PF potential free Reception of the control signal via radio Safety advice If the wireless connection between the control unit and the RF MSG is interrupted connected devices can no longer be operated For that reason do not connect drives to RF MSGs which could be hazardous to human life Technical specifications RF MSG Installation Mounting Protection rating IP 20 Dimensions approx 38 x 4...

Страница 3: ... Radio frequency 868 2 MHz Teaching the radio connection Please teach each RF MSG separately If several motor control units are going to be operated from one supply cable it is an advantage to teach the RF MSG before the installation 1 Put the control unit remote control into the teaching mode observe the corresponding manual data sheet 2 Activate the RF MSG voltage supply The motor control unit l...

Страница 4: ...uctions are disregarded any guarantee or warranty claim expires After being unpacked the device must be immediately be checked for any possible mechanical damage The supplier shall be immediately notified in the event of any transport damage The RF MSGs must not be used if damaged If it is assumed that danger free operation can no longer be guaranteed the device must be taken out of service and se...

Отзывы: