RF-MSG Issued 17.05.2010 The right to make technical alterations is reserved. Errors subject to correction.
3
RF-MSG-PF
Installation:
Mounting
Protection rating:
IP 20
Dimensions:
approx. 38 x 47 x 29 (W x H x D, mm, plus flexible
antenna)
Weight:
approx. 60 g
Ambient temperature:
Operation -20…+70 °C, Storage -55…+90°C
Ambient air humidity:
max. 95% rH, avoid condensation
Operating voltage:
230 V AC
Input:
Operating voltage (Mains L1/N/PE)
Output:
1 × Drive 230 V (Up/Down/L),potential-free,
loadable with max. 4 A / 230 V AC
Radio frequency:
868.2 MHz
Teaching the radio connection
Please teach each RF-MSG separately!
If several motor control units are going to be operated from one supply cable, it is an
advantage to teach the RF-MSG before the installation.
1.
Put the control unit/remote control into the teaching mode (observe the
corresponding manual/data sheet).
2.
Activate the RF-MSG voltage supply. The motor control unit learns a connection to
the control unit/remote control on its own 3 seconds after the mains voltage is
applied.
Only one motor control unit can be recognised at a time.
3.
Note the feedback from the control unit (“Teaching completed”).