background image

RF-MSG Issued 17.05.2010 The right to make technical alterations is reserved. Errors subject to correction. 

Product description 

RF-MSG and RF-MSG-PF are radio controlled motor control units for WS1000 Color, 

WS1 Color and KNX WS1000 Color control units. A drive (e.g. shade or window) can be 

connected to the control units.  

Drives connected to RF-MSG and RF-MSG-PF can also be operated directly with the 

Remo 8 radio remote control (without an additional control unit). 

 

Functions:  

 

1 connection for 230 V drive  

RF-MSG:

 with potential 

RF-MSG-PF:

 potential-free 

 

Reception of the control signal via radio 

 

Safety advice 

If the wireless connection between the control unit and the  

RF-MSG is interrupted, connected devices can no longer  

be operated. For that reason do not connect drives to  

RF-MSGs which could be hazardous to human life! 

 

Technical specifications  

RF-MSG 

Installation:  

Mounting 

Protection rating:  

IP 20 

Dimensions:  

approx. 38 x 47 x 29 (W x H x D, mm, plus flexible 

antenna) 

Weight:  

approx. 60 g 

Ambient temperature: 

 

Operation -20…+70°C, Storage -55…+90°C 

Ambient air humidity:  

max. 95% rH, avoid condensation 

Operating voltage:  

230 V AC 

Input: 

Operating voltage (Mains L1/N/PE)  

Output:  

1 × Drive 230 V (PE/N/Up/Down),  

loadable with max. 4 A / 230 V AC 

Radio frequency:  

868.2 MHz 

 

 

Содержание RF-MSG

Страница 1: ...ion 1 20 onwards Technical specifications and installation instructions Elsner Elektronik GmbH Steuerungs und Automatisierungstechnik Herdweg 7 D 75391 Gechingen Germany Phone 49 0 70 56 93 97 0 Fax 49 0 70 56 93 97 20 info elsner elektronik de www elsner elektronik de ...

Страница 2: ...al RF MSG PF potential free Reception of the control signal via radio Safety advice If the wireless connection between the control unit and the RF MSG is interrupted connected devices can no longer be operated For that reason do not connect drives to RF MSGs which could be hazardous to human life Technical specifications RF MSG Installation Mounting Protection rating IP 20 Dimensions approx 38 x 4...

Страница 3: ... Radio frequency 868 2 MHz Teaching the radio connection Please teach each RF MSG separately If several motor control units are going to be operated from one supply cable it is an advantage to teach the RF MSG before the installation 1 Put the control unit remote control into the teaching mode observe the corresponding manual data sheet 2 Activate the RF MSG voltage supply The motor control unit l...

Страница 4: ...uctions are disregarded any guarantee or warranty claim expires After being unpacked the device must be immediately be checked for any possible mechanical damage The supplier shall be immediately notified in the event of any transport damage The RF MSGs must not be used if damaged If it is assumed that danger free operation can no longer be guaranteed the device must be taken out of service and se...

Отзывы: