Operating the display
Solexa II Control
• from software version weather station 1.3, display 2.1 • Version: 11.05.2017
Technical changes and errors excepted.
Frost alarm (combination of precipitation and low outdoor temperature).
Window closed.
Rain alarm.
Depending on the setting, the window is either closed or in the rain position.
Timer functions:
Timed closure or timed opening active.
Outdoor temperature:
Outdoor temperature is OK. Ventilation is released.
If the
not
symbol is displayed, the outdoor temperature block is active.
Ventilation function:
Indoor temperature for ventilation has been exceeded.
Ventilation is performed if all other conditions are OK.
Light
The detailed description of the automatic functions is in the
Light - Automatic mode
chapter in the manual.
Values below twilight threshold value. Lights are switched on after a delay of
1 minute. If a lighting time period has also been set, the lights are only switched
on during this period.
Lighting time period active. If twilight switching has also been set, the lights are
only switched on in twilight.
Heating
The detailed description of the automatic functions is in the
Heating - Automatic mode
chapter in the manual.
Day mode. Only the day temperature value set is valid.
Night mode (night period). Only the night temperature value set is valid.
Currently valid reference temperature value not reached. Heating is turned on.
Roof gutter heating
The detailed description of the automatic functions can be found in the
Roof gutter
heating - Automatic mode
chapter in the manual.