Installation 

 

Remove the back cover from the keypad using the supplied security screwdriver

 

 

Code the transmitter to the receiver prior to mounting the Keypad 

 

Drill 4 holes on the wall for the screws and 1 hole for the cable

 

 

Fix the back firmly on the wall with 4 flat head screws

 

 

Thread the cable though the cable hole

 

 

Attach the keypad to the back cover

 

 

Specifications 

Operating Voltage 

 

12 to 24 VDC or 12 to 18 VAC

 

User Capacity

 

2,000 

Active Current 

 

65mA

Idle Current

 

35mA

Operating 
Temperature 

 

-20°C - 50°C

Operating Humidity

10 % - 90% RH

Adjustable 
Transmission Time

 

1- 90 seconds

Operating Range 

Up to 50 metres with line of sight 

Dimensions

 

128 x 82 X 28mm

Weight 

700g

 

 

Wiring 

Wire Colour

 

Function

 

Red

 

AC or DC Supply, + for DC

 

Black

 

AC or DC Supply, - for DC

 

Green 

Wiegand 26 Bit Output D0 

White 

Wiegand 26 Bit Output D1 

Blue 

Wiegand Ground GND 

Содержание PCKeypad

Страница 1: ...User Manual PCKeypad Wireless Keypad...

Страница 2: ...PCKeypad conforms to Ingress Protection 65 The PCKeypad supports up to 2000 users with 4 to 8 digit PIN These features make PCKeypad an ideal choice for gate and door access for homes shops factories...

Страница 3: ...Attach the keypad to the back cover Specifications Operating Voltage 12 to 24 VDC or 12 to 18 VAC User Capacity 2 000 Active Current 65mA Idle Current 35mA Operating Temperature 20 C 50 C Operating Hu...

Страница 4: ...with one beep This indicates a successful reset Programmed user ID and user PIN is retained even after factory reset Transmission time The transmission time of the built in PentaCode transmitter is a...

Страница 5: ...usly without existing from programming mode as follows 1 User ID No PIN User ID No 2 PIN Press to Exit Delete a user Orange light confirms you are in delete mode Green light flash indicates a user has...

Страница 6: ...ed led light Factory default Press to Exit To set keypad tone 7 8 To disable the keypad tone 7 9 To enable the keypad tone Factory default Press to Exit Keypad Lockout Note The below changes can only...

Страница 7: ...witch to the receivers 12 way dip switch DO NOT USE THE DEFAULT FACTORY SETTING FOR THE 12 WAY DIP SWITCH AS THIS IS A COMMON CODE 3 Test the keypad by typing in a valid user pin code Encrypted Coding...

Страница 8: ...Keep this document in a secure and safe place User ID Number Name of User Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Use Microsoft Excel to create a longer list 2000 User ID...

Отзывы: