Quick Start Instructions 

 

1.  Place operator in correct position (Pinion wheel to be parallel to the gate and stepped out 

to allow for width of rack once it is mounted onto the gate frame). Mark out fixings and fix 
operator to the concrete pad. 

 

2.  Fix rack to the gate frame keeping 1mm-2mm clearance between the rack teeth and Pinion 

wheel. 

 

3.  Once the rack is fixed move the gate and sight the rack moving over the pinion wheel, 

check that most of the pinion wheel meshes with the rack. Make sure rack runs freely over 
the pinion wheel, any tights spots should be corrected by adjusting the rack height. Check 
the operator is firmly bolted down to the concrete pad. 

 

4.  Ensure stops are installed on the gate for the fully closed and fully open positions. 

 

Connect Photo Electric Beams, Safety Bump Strip and all other safety devices as required. 

 

Limit Switch Adjustment 

 

Elsema’s iS1500 motor kits are equipped with dual limit sensors. The 1

st

 limit slows the gate and 

the 2

nd

 limit stops the gate. The stop limit in one direction becomes the slow limit in the opposite 

direction automatically. 
 
Move the gate into full close position and adjust the magnet on the gate so it aligns with the Stop 
limit in the closing direction. 
 
Move the gate into fully open position and adjust the magnet on the gate so it aligns with the Stop 
limit in the opening direction. 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

Содержание iS1500

Страница 1: ...HIGH SPEED SLIDING GATE OPENER Model iS1500 Elsema s Eclipse Control Card USER MANUAL...

Страница 2: ...ose options are used Display any necessary signs to indicate any danger areas and automatic operation of the gate or door The operators are not designed to be used in any hazardous areas or areas subj...

Страница 3: ...re tighten wing nut Mechanical Installation Ensure gate rolls easily and has been installed in a manner where there is no excessive friction or binding occurring A concrete base approximately 600mm l...

Страница 4: ...4 Plan View Layout Conduit Position...

Страница 5: ...adjusting the rack height Check the operator is firmly bolted down to the concrete pad 4 Ensure stops are installed on the gate for the fully closed and fully open positions Connect Photo Electric Bea...

Страница 6: ...led on either side open or close Please see the diagram below to locate the marking on the magnets Fig 6 When steel gear rack is used or gear rack which are much slimmer you will have to use the packi...

Страница 7: ...now be opened by hand To re engage the clutch move the gate by hand into approx the halfway position and turn the knob clockwise until it is very tight If when turning the knob clockwise and it just...

Страница 8: ...ensure operator will not run inadvertently Gate rolls freely when in manual Gate wheels and guide rollers in good condition Gate stops are installed and in good condition not loose Gate rack is tight...

Отзывы: