ELRO PRECIJET+ Скачать руководство пользователя страница 4

 

Page 3 

3EE490044EU – 09/19 

 

 

ELRO-Werke AG 
Wohlerstrasse 47 
5620 Bremgarten 

 

1. 

RECOMMENDATIONS 

 

 

These appliances are for professional use, only appropriately trained personnel should use them. 

 

These appliances are intended to be used for commercial applications, for example in kitchens of restaurants, canteens, hospitals and in 
commercial enterprises such as bakeries, butcheries, etc., but not for continuous mass production of food. 

 

These appliances must be installed with sufficient ventilation to prevent the formation of an excessive concentration of substances harmful for 
health within the premises in which they are installed. 

 

The rate of new air required for combustion is 2m3/h per kW of heating power. 

 

The equipment is not designed to work in an explosive atmosphere. Accordingly it must not be installed in an area covered by the ATEX directive. 

 

Never block the condensate exhaust flue, because the pressure could rise in the appliance and pose a risk of explosion. 

 

If an error message appears consult the list of error messages and follow the ADVICE given 

 

When cleaning high pressure jets or lances should never be used. 

 

NEVER start the oven WITHOUT HAVING POSITIONED AND LOCKED the ventilation duct. 

 

Do not remove the ventilation duct and the drain grid located in the oven. If this grid is missing do not start the oven. 

 

 

 

Drain grid 

 

 

Always use a qualified technician to install the equipment and if necessary change the oven from one gas to another. 

 

IMPORTANT: Please be aware that when cooking dishes prepared with alcohol (coq au vin, pears in wine, etc.…). Vapour saturated with alcohol 
may when heated cause an explosion in the oven and due to the sealed door, create a momentary overpressure which may cause an irreversible 
deformation of the panels. This risk is further increased when the user adds alcohol to the products near the end of the cooking cycle and closes 
the door to complete cooking. 

 

The appliance must be isolated electrically during cleaning or maintenance and when replacing parts. 

 

The control panel is operated via a serigraphic touch screen using your fingers. We recommend the exclusive use of your fingers and no other 
items such as knives, forks or spoons etc. 

 

For long term reliability and safety it is advisable to have the unit serviced by suitably qualified technicians 

(Dismantling of burners, 

inspection and cleaning of venturis, cleaning nozzles, adjustment of air rings, cleaning vents, checking for possible leaks, checking control 
elements, regulating and safety accessories…). 

 

The oven must be meticulously maintained on a DAILY basis (see the “Maintenance” chapter). In particular, the fans, heating elements 
and walls must be kept clean, without accumulation of grease and mineral deposits (lime or other). 

 

Preheating (20 level ovens): Whatever the cooking mode, these ovens are designed to be preheated with the trolley in place. See « Practical 
operating advice ». 

 

Using a trolley or preheating plate (optional) is compulsory for automatic cleaning of 20 level ovens. 

 

It is strictly forbidden to open the door of the oven during the cleaning cycle. 

 

Never place the core probe behind the ventilation duct (the probe could be damaged by the fan, an element or the gas heat exchange). 

 

THE APPLICATION OF ANY CLEANING PRODUCT ONTO A HOT SURFACE, OVER  60°C, IS STRICTLY FORBIDDEN. The surface will be 
damaged beyond repair (darkened, virtually black). 

 

Combination ovens should be cleaned with specific products which can resist temperature of up to 70°C. An inappropriate cleaning or descaling 
product may have a slightly corrosive effect. 

 

The detergent chemical risk should not exceed 3 in accordance with EN 1717 (Toxicological information FDS: LD50 > 200mg/kg). 

 

We strongly recommend the use of cleaning products supplied by the manufacturer to ensure good results and optimize the service life of its 
components. 

Except for the UK market: No detergent product is recommended or supplied. Any detergent used with this appliance must have been verified to 
represent no greater risk than Fluid Category 3. If the detergent used represents a Fluid Category risk greater than Fluid Category 3 alternative 
backflow protection to the double check valve supplied with the appliance will be required immediately upstream of the appliance. The backflow 
protection used must be appropriate to the risk posed by the detergent.  

 

In order to ensure optimum cleaning results without the risk of chemical attack we recommend using our cleaning chemical BK101. Other 
products can be used. Generally cleaning products that are compatible with our ovens should: 

- have a composition based on potassium hydroxide with a concentration < 25%, WITHOUT sodium hydroxide 
- be suitable for use at a temperature of 60°C. 
- include anticorrosion agents 

 

For maximum efficiency of the descaling product without damaging the material and components of the oven, you should use an appropriate 
descaler. The use of certain acids has an irreversible destructive effect that may cause significant damage. The descaling product must contain 
corrosion inhibitors to prevent metal attack. It must also comply with legal requirements, in particular for material intended to come into contact 
with foodstuffs.  

Chemical products containing nitric acid are strictly prohibited. Recommended composition: 

- Phosphoric acid <50% 
- Corrosion inhibitor 

 

The automatic cleaning system is exclusively designed to achieve an introduction of cleaning and degreasing chemical. Never use a descaling 
agent. This would damage the hydraulic system of the oven irreversibly. 

 

Under no circumstances should the oven be cleaned with grills or containers in situ.  

 

The core probe socket and USB port are fitted with silicone protective covers. 

- Always put the protective cover in place (lowered to protect connections) whenever the socket is not in use. 
- Never “clean” connections with a water hose or a sponge. (If the silicone cover is used and put back in place after use, 

no maintenance is necessary). 

Содержание PRECIJET+

Страница 1: ...k is available to provide you with a personalized contract WARNING The product delivered to you complies with current standards If any modifications are made the manufacturer cannot accept any respons...

Страница 2: ...5 1 DEFERRED START 12 6 AUTO MENU 13 6 1 AUTOMATIC PROGRAMMED RECIPES 13 6 2 FAVOURITE RECIPE 13 6 3 MULTI PRODUCTS SCREEN 14 6 4 TYPE OF DISPLAY 14 6 5 LIST OF PRE RECORDED PROGRAMMES 15 7 TOOL BOX M...

Страница 3: ...ANCE OF THE OVEN 28 14 1 MAINTENANCE OF EXTERNAL SURFACES 28 14 2 CLEANING THE ELECTRONIC COMPARTMENT VENTILATION OPENINGS 28 14 3 CLEANING THE CAVITY GASKET 28 14 4 MAINTENANCE OF INTERNAL SURFACES 2...

Страница 4: ...ctical operating advice Using a trolley or preheating plate optional is compulsory for automatic cleaning of 20 level ovens It is strictly forbidden to open the door of the oven during the cleaning cy...

Страница 5: ...uirer The warranty will not cover problems caused by failure to comply with these recommendations Warning Danger Caution Cooking appliances may reach 250 C BE CAREFUL not to burn yourself when using o...

Страница 6: ...seal Control panel Door handle Wire or sheet duct Data plate visible with the door open USB port Core probe socket Oven legs height adjustable Door channel 2 2 20 LEVEL OVENS Motorised vent valve Cav...

Страница 7: ...t 2 3 2 10 LEVEL OVENS GN1 1 Banqueting runner Device GN1 1 Runners Trolley spaced 65 GN2 1 Runners Trolley spaced 65 GN1 1 Banqueting Trolley 30 plates spaced 66 GN1 1 runners kit 20 level GN2 1 Banq...

Страница 8: ...olley spaced 65 GN2 1 Runners Trolley spaced 65 Grease Filter Kit Preheat Plate Banqueting isothermic Hood Banqueting isothermic Hood 2 3 1 ALL MODELS Core Probe Kit Delicate products 1 pt dia 1 7x100...

Страница 9: ...rs trolley 20 level GN 2 1 160 Kg Banqueting or Runners trolley 3 3 USING THE SUPPORTS Runners modules and trolleys 3 3 1 SUSPENDED RUNNERS On 6 and 10 level ovens To remove the suspended runners from...

Страница 10: ...t if it isn t being used see drawing opposite Ovens with trolley 20 level Store the probe in the holder provided on the ventilation duct see drawing opposite During cooking or with a core temperature...

Страница 11: ...ill result in uneven browning and inconsistent results reduce the load to obtain good results after selecting Convection mode with Vent open 3 6 PREHEATING 20 level oven Irrespective of the mode these...

Страница 12: ...etc You need only touch the screen with your finger to access parameters and information The welcome menu is displayed briefly when the unit is switched on then replaced by the Manual menu For stacke...

Страница 13: ...uired to treat hard water to avoid a build up of lime scale in the boiler and excessive consumption of descaling product Steam usage level Water hardness GN 1 1 oven GN 1 1 oven Medium 3 to 7 hours da...

Страница 14: ...pes in total each with 6 cycles 6 Principle families with direct access to the recipe Recipes can be edited Copied Created Modified Deleted Detailed display Multi Level programme 10 independent timers...

Страница 15: ...4 Recipe finished Level free for a new recipe Pressing only displays recipes in My favourites library compatible with the recipe that is running Erases all the recipes that have finished or not yet s...

Страница 16: ...resh steamed fish Steam 98 8 Yes Preheating 100 Fish Frozen steamed fish Steam 98 12 Yes Preheating 100 Fish Roast fish 500g Combi 20 165 10 No Preheating 170 Fish Fresh seafood Steam 90 3 Yes Preheat...

Страница 17: ...n parameters Technical After sales Maintenance information 7 1 PASSWORD Allows the client access to Data exchange Client parameters Change the Manual Auto cleaning 0000 Changeable PIN Code CHEF Pass w...

Страница 18: ...Default volume of detergent container Capacity in litres of the water treatment system Reset Set to zero by default if the oven doesn t have a dedicated water treatment system Software reset Attentio...

Страница 19: ...been set in Client parameters This counter is only used if the unit has two separated water supplies Warning message This message appears every time the oven is switched on if the programmed water ca...

Страница 20: ...container if the supply pipe is empty select this function ensures the dosage volume will be sufficient to ensure efficient results Procedure Unhook the side runners lean them to one side within the c...

Страница 21: ...evel of clean required and the time by pressing the corresponding touch button then validate Programming screen The automatic cleaning programme is displayed The cleaning cycle will start at the set h...

Страница 22: ...6 REPLACEMENT OF THE CHEMICAL CONTAINER The cleaning chemical supply hose is labelled which correspond to the container Never use descaling product into the automatic cleaning system This could seriou...

Страница 23: ...ymbols before the name How do you change the name of a client recipe The names of client recipes can be personalised Modify click on the zone name or family Change the name or family Why can t I chang...

Страница 24: ...and yearly intervals for water gas electricity and detergent Costs are also displayed if the actual costs have been put into the corresponding fields in Client parameters What is Safe Mode In the even...

Страница 25: ...ll vary of course with the kind of product and the cooking level desired WARNING The cooking of a product does not stop at once when removed from the oven As a matter of fact after standstill the core...

Страница 26: ...e for the aspect external and sliced for diminishing weight loss but also for being safer from a hygienic point of view in the preparation of food products The quality of cooking is also much less sen...

Страница 27: ...vice technician E68 Cavity at 290 C Cooking stops Switch the oven off and call a service technician E72 Electronics at over 75 C Cooking stops Switch the oven off and call a service technician i81 Wat...

Страница 28: ...continue to act over time with the risk of starting the corrosive process Worse still if the affected surface is submitted to temperatures over 60 C inside of an oven a tank or tank the impact will be...

Страница 29: ...NG THE ELECTRONIC COMPARTMENT VENTILATION OPENINGS Cooling the electronic compartment is ensured by means of the ventilation apertures at the right front of the equipment 6 and 10 level Once a week ch...

Страница 30: ...on stainless steel thus the composition recommended is phosphoric acid with a concentration of less than 50 tensio active corrosion inhibitors diluted to a known level conforming to the product label...

Страница 31: ...rfaces x Respect cleaning product dosage Rinse thoroughly Alert the after sales service if any rust points appear Checking the amount of cleaning agent in the container x Replace the container as ofte...

Страница 32: ...he problem In no circumstances should the defect be remedied by the user or a third party Regular service inspections and maintenance by our engineers are an essential condition for correct and reliab...

Отзывы: