59
LED on remote control not illuminating, or is
dim when unit is operated
1. Ensure battery is connected with correct polarity
2. Ensure battery connections are good
3. Replace battery
PIR Detector false alarming
1. Ensure that the detector is not pointing at a
source of heat or a moving object
2. Ensure that the detector is not mounted above a
radiator or heater
3. Ensure that the detector is not facing a window
or in direct sunlight
4. Ensure that the detector is not in a draughty
area
5. Sensitivity detection set too high –reset to low
sensitivity detection
PIR Detector not detecting a person’s movement
1. Check battery connections are good.
2. Sensitivity detection set too low– reset to high
sensitivity detection.
3. Check that the detector is correctly set up.
4. Ensure DIP switches 1-2 of SW2 are correctly
set.
5. Ensure that detector is mounted the correct way
up.
(i.e. with detection window at the bottom)
6. Ensure that the detector is mounted at the
correct height, (i.e. 2-2.5m).
7. Allow up to three minutes for detector to
stabilize.
PIR Detector LED flashes on detection of
movement, (device in normal operation mode)
1. Low battery – replace battery.
Event & Schedule not working under disarm,
fully arm and partial arm
Set ‘Event & Schedule’ to on
Magnetic Contact Detector not working
1. Ensure batteries are connected with correct
polarity.
2. Ensure battery connections are good.
3. Ensure ‘Code Learning’ emitted to Control Unit
is correctly proceeded.
4. If no external contacts are connected ensure
correct setting is made on the DIP switch
5. If external contacts are connected
a. Check that all contacts are closed.
b. Check all contacts are wired in series.
Magnetic Contact Detector false alarming
1. Ensure that gap between magnet and detector
is less than 10mm.
2. Tamper switch below battery cover not
depressed – check battery cover is fitted
correctly and that fixing lugs are not broken.
LED on Magnetic Contact Detector illuminating
when door or window is opened.
1. Low battery – replace batteries.
DIGITAL DIALER TRANSMISSION
PROTOCOL
Contact ID Event Codes
Definition
Code
Fire/Smoke Alarm
110
Panic Alarm
120
Intruder Alarm
130
24hr Intruder
133
System Tamper
137
AC Failure
301
System Low Battery
302
Sensor Tamper
383
Sensor Low Battery
384
Cancel/Abort Alarm
406
System Test
601
Disarm(Open)/Arm(Close) by User
401
Periodic Test Report
602
Flood Alarm
113
Gas Alarm
151
A501111603R01