30
This section is for setting of adding and categorizing of
security devices (e.g. PIR detector). Scroll through
the programming menu until
‘3. SECURITY SENSOR
ZONE’
is displayed and press .
Enter the sensor zone number to be configured and
press .
CODE LEARNING
This enables the Smart Home Box learns ID from each
detector.
Scroll through the menu until
‘:1 Learning ID’
is
displayed and press .
Pressing tamper switch/learning key on the detector
will emit ID code to the Smart Home Box instantly.
Three possibilities would happen as follows:
Learning OK
– the ID code was learned by the Smart
Home Box successfully.
Time Out
– the time involved for learning the ID code is
60s. During this duration, fail to press the tamper
switch/learning key on the detector would result in
overdue programming.
ID Duplicate
– the same ID code was learned by the
Smart Home Box beforehand.
Note:
Once code learning is completed, it is
recommended to assign appropriate Model Type and
Security Type for the learned detectors to ensure
central monitoring station receives correct event codes
when event occurs. Please note, to receive code
number 113 (Flood Detector) and 151 (Gas Alarm), the
Model Type must be assigned as Flood Detector and
Gas Detector.
For wire zone (33-36), the function of
‘:1 Wire Zone’
is
disabled.
LOCATION
Default setting: ‘None’
Scroll through the menu until
‘:2 Location’
is displayed.
To change the setting press .
Scroll through available options until the required
setting is displayed.
Press to save and exit, or
Press to exit without saving.
MODEL
Each detector can be defined as one of model types.
Scroll through the menu until
‘:3 Model Type’
is
displayed. The current setting will also be displayed.
To change the setting press .
Scroll through available options until the required
setting is displayed. Once the model type is selected,
the security type is chosen as well. The following
shows the security type each model is categorized to:
Intruder
PIR Detector, Magnetic
Fire
Fire/Smoke Detector
Panic/PA
Flood Detector, Gas Detector and CO Detector
Press to save and exit, or
Press to exit without saving.
SECURITY TYPE
Each sensor zone may be programmed to operate in
one of 4 different modes depending on the type of
alarm function it is required to perform. The following
security types are available:
Intruder
- provides standard intruder monitoring with ARM
functions.
24 Hour Intruder
- used to provide 24 hour monitoring of areas
requiring continuous security protection even the
system is disarmed, (e.g. gun lockers). Activation
of any detector on a security zone will immediately
initiate a Full Alarm condition.
Fire