Controller for Milk Cooling and Milk Storage
Applications

z

z

z

z

z

Replaces single Thermostats,
Digital Displays and Stirrer Timers

z

z

z

z

z

Stirrer Control, adjustable

z

z

z

z

z

Digital Temperature Display for Actual Values
and Setpoints, °C or °F

z

z

z

z

z

Min/Max Memory

z

z

z

z

z

Over-/Undertemperature Alarm,
Alarm Relay, Emergency Mode

z

z

z

z

z

Foil Keypad, Housing for Panel-/Door Mounting

Operating Elements

Parameters

All selectable parameters hold a parameter number (e.g. P02), you
will find a listing on the next page.

Calling up and editing

Press key "P" ................................... parameter number appears
Use "

×

/

Ø

" ............................................ select desired parameter

Press "P" again .................................... parameter value appears
Use keys "

×

/

Ø

" ....................................... adjust parameter value

Press "P" again ................ value is stored, back to parameter no.

Unlock Keys

To prevent un-authorized persons from editing parameter values,
there is a locking function which allows only the most important
parameters to be changed at any time. The access code can
entered as follows:

Press key "P" ................................... parameter number appears
Use "

×

/

Ø

" ....................................... select code parameter (P15)

Press "P" again .................................... parameter value appears
Use key "

×

" ................................................. set code No. to "88"

Press "P" again ................ value is stored, back to parameter no.

If no key is hit for about four minutes, the editing function is locked
again.

Auto scrolling

Hold "

×

/

Ø

"-keys to scroll values automatically.

Manual Stirrer Control

While the Actual Value is visible:
Hold key "P" >3 seconds ............... Stirrer starts, LED flashes.
Stirrer stops automatically when timer P06 is run down
or
Hold key "P" >3 seconds ............... Stirrer stops, LED off.

Reading the Minimum/Maximum Value

While the Actual Value is visible, the highest and the lowest
occured temperature value can be read:

• Hold key "

×

" until "H1" appears, then release key.

For the next 3 seconds the display shows the highest value.

• Hold key "

Ø

" until "L0" appears, then release key.

For the next 3 seconds the display shows the lowest value.

Erase the Minimum/Maximum Memory

Read any Min/Max Value, then press "P"-key immediately until
"del " appears. Now the memory is erased.

Reset Temperature Alarm

Press any key.

Stirrer

Blinking: Manually ON

Continuous: Automatically ON

Decimal Point

Decrease 

Values

TAR

Cooling ON

Increase 

Values

ELREHA

P

Alarm

Blinking: Reset,

but still available

Programming

key

Please note Safety Information
on Page 3 !

No. 5311231-02/00E

Softw.Vers. al05xxxx

Milk Cooling Controller

TARN 1600