TECHNICAL PARAMETERS
The parameters and functions comply with the requirements of the EU Directive 2009/125/EC
and the EU Regulation 2015/1188 with regard to ecodesign requirements for local space radiators.
Model identifier(s): 1316.144, 1316.120, 1316.154K, 1316.152K, 1380.244K, 1380.220K, 1381.044, 1381.020,
1382.044, 1383.044, 1383.020, 1384.044, 1384.020, 1386.044, 1386.020, 1387.044, 1387.020, 1440.044, 1440.020,
1440.184K, 1440.182K, 1441.044, 1441.020, 1444.044, 1444.020, 1445.044, 1445.020, 1446.044, 1446.020
Parameter
Symbol
Value
Unit
Parameter
Unit
Heat output
Type of heat output /
room temperature control
Nominal heat output:
1316.144 (1316.120, 1380.044, 1380.020,
1440.044, 1440.020)
1316.154K (1316.152K)
1380.244K (1380.220K)
1381.044 (1381.020, 1441.044, 1441.020)
1382.044 (1382.020)
1383.044 (1383.020)
1384.044 (1384.020, 1444.044, 1444.020)
1386.044 (1386.020)
1387.044 (1387.020)
1440.184K (1440.182K)
1445.044 (1445.020)
1446.044 (1446.020)
Pnom
1,0
1,5
2,0
0,7
0,6
0,4
1,25
0,35
0,8
1,8
0,5
0,35
kW
Electronic room temperature
control with week timer
Yes
Other control options
Room temperature control
with open window detection
Yes
With adaptive start control
Yes
Minimum heat output (indicative)
1316.144 (1316.120, 1380.044, 1380.020,
1440.044, 1440.020)
1316.154K (1316.152K)
1380.244K (1380.220K)
1381.044 (1381.020, 1441.044, 1441.020)
1382.044 (1382.020)
1383.044 (1383.020)
1384.044 (1384.020, 1444.044, 1444.020)
1386.044 (1386.020)
1387.044 (1387.020)
1440.184K (1440.182K)
1445.044 (1445.020)
1446.044 (1446.020)
Pmin
1,0
1,5
2,0
0,7
0,6
0,4
1,25
0,35
0,8
1,8
0,5
0,35
kW
Maximum continuous heat output:
1316.144 (1316.120, 1380.044, 1380.020,
1440.044, 1440.020)
1316.154K (1316.152K)
1380.244K (1380.220K)
1381.044 (1381.020, 1441.044, 1441.020)
1382.044 (1382.020)
1383.044 (1383.020)
1384.044 (1384.020, 1444.044, 1444.020)
1386.044 (1386.020)
1387.044 (1387.020)
1440.184K (1440.182K)
1445.044 (1445.020)
1446.044 (1446.020)
Pmax,c
1,0
1,5
2,0
0,7
0,6
0,4
1,25
0,35
0,8
1,8
0,5
0,35
kW
Auxiliary electricity consumption
At nominal heat output
elmax 0,00086
kW
At minimum heat output
elmin 0,00086
kW
In standby mode
elSB
0
none
kW
www.elpe.pl
tel. (12) 651 11 00, fax (12) 651 11 11,
Tadeusza Śliwiaka 16, 30-797 Kraków, Poland
ELPE Elektroprodukt