Hardwar
Hardware Troubles
e Troubleshooting
hooting
55
55
E281-2310 Controller Protocol
E281-2310 Controller Protocol
The ten-byte binary data format displayed in hex by COMDUMP for correct
The ten-byte binary data format displayed in hex by COMDUMP for correct
operation with Elo driver software is as follows:
operation with Elo driver software is as follows:
B
By
ytte
e
D
De
es
sc
crriip
pttiio
on
n
1
1
A
AS
SC
CIII
I ''U
U'
' ((5
55
5h
h))
2
2
A
AS
SC
CIII
I ''T
T'
' ((5
54
4h
h))
3
3
S
Stta
attu
us
s B
By
ytte
e
4
4
X
XL
Lo
ow
w
5
5
X
XH
Hiig
gh
h
6
6
Y
YL
Lo
ow
w
7
7
Y
YH
Hiig
gh
h
8
8
Z
ZL
Lo
ow
w
9
9
Z
ZH
Hiig
gh
h ((d
de
effa
au
ulltts
s tto
o 0
0))
1
10
0
C
Ch
he
ec
ck
ks
su
um
m
E281A-4002 Controller Protocol
E281A-4002 Controller Protocol
If the controller is jumpered for E281A-4002 emulation mode, the output will be
If the controller is jumpered for E281A-4002 emulation mode, the output will be
the six-byte binary format as follows:
the six-byte binary format as follows:
B
By
ytte
e
M
MS
SB
B
L
LS
SB
B
1
1
1
1
1
1
X
X1
11
1
X
X1
10
0
X
X9
9
X
X8
8
X
X7
7
X
X6
6
2
2
1
1
0
0
X
X5
5
X
X4
4
X
X3
3
X
X2
2
X
X1
1
X
X0
0
3
3
0
0
1
1
Y
Y1
11
1
Y
Y1
10
0
Y
Y9
9
Y
Y8
8
Y
Y7
7
Y
Y6
6
4
4
0
0
0
0
Y
Y5
5
Y
Y4
4
Y
Y3
3
Y
Y2
2
Y
Y1
1
Y
Y0
0
5
5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
6
6
0
0
0
0
0
0
0
0
Z
Z3
3
Z
Z2
2
Z
Z1
1
Z
Z0
0
In this mode, the first four bytes in each packet will be decreasing, followed by a
In this mode, the first four bytes in each packet will be decreasing, followed by a
zero byte, and a byte from 00 to 0F (hex). The Z value (byte 6) will be 00 when
zero byte, and a byte from 00 to 0F (hex). The Z value (byte 6) will be 00 when
you lift your finger.
you lift your finger.
Using the TOUCHES Utility
Using the TOUCHES Utility
TOUCHES is a DOS utility included on the
TOUCHES is a DOS utility included on the
DOS and
DOS and Window
Windows Driver Di
s Driver Disk
sk
..
TOUCHES works through the ELODEV driver making it useful for further
TOUCHES works through the ELODEV driver making it useful for further
diagnosis of hardware or calibration problems under DOS. Run TOUCHES by
diagnosis of hardware or calibration problems under DOS. Run TOUCHES by
typing "TOUCHES". Detailed instructions for using this utility can be found in
typing "TOUCHES". Detailed instructions for using this utility can be found in
the
the
TOUCHES
TOUCHES
section of the
section of the
DOS and W
DOS and Windows Dr
indows Driver Guide
iver Guide
..
Unlike COMDUMP, which displays a stream of bytes in hexadecimal,
Unlike COMDUMP, which displays a stream of bytes in hexadecimal,
TOUCHES displays decimal coordinate data. If ELODEV has been calibrated,
TOUCHES displays decimal coordinate data. If ELODEV has been calibrated,
coordinates will be scaled 80x25. If ELODEV is loaded without the -c calibration
coordinates will be scaled 80x25. If ELODEV is loaded without the -c calibration
flag, and ELOCALIB is not run, raw coordinates will be displayed.
flag, and ELOCALIB is not run, raw coordinates will be displayed.
Содержание IntelliTouch Ultra
Страница 1: ...IntelliTouch IntelliTouch Ultra Ultra Product Manual Product Manual Revision 3 2 Revision 3 2...
Страница 5: ...iv iv...
Страница 11: ...x x...
Страница 17: ...6 6 Chapter 1 Introduction Chapter 1 Introduction...
Страница 35: ...24 24 Chapter 3 Touch Monitor Installation Chapter 3 Touch Monitor Installation...
Страница 61: ...50 50 Chapter 4 Component Installation Chapter 4 Component Installation...