4.0 Testing
Plug the adapter to the Ethernet network. Power up the adapter.
After a second should light up an orange indicator LNK (close to
the Ethernet socket).. In a minute should LNK indicator (orange)
light on. If not, the cable may be defective or improper wired (when
connecting to the endpoint like PC – you should use cross-over UTP
cable, in other cases use straight UTP cable) or power supply is not
good or module might be damaged. In a while the green indicator
ACT starts blinking indicating a network traffic. Make sure drivers
are installed (see chap. 3.5). Start
DigiWiz.
application from
supplied CD-ROM and click “
Next
” to discover the adapter. If it
appears in the window, installation was successful. Finish the
DigiWiz application (
click “
Next
”). See the port number in Device
Manager. Connect loopback to the RS232 port (connecting Tx and
Rx together) and run the
Autotest
application from the installation
CD-ROM. Fill up the port number and click “
Start data transfer
”. If
everything is O.K, the message “Data transfered successfully”
appears; while if not, the error message “Timeout on Device Read”
will be seen.
For testing purpose can be helpful a HyperTerminal, which is part
of the operating system MS Windows.