background image

ELOE218ZK002

 

 

6

 

 

3.3.3  Virtual port properties setting 

When connection is established the adapter virtual port appears as the next COM port 
in 

the 

Správce 

za

ř

ízení

.

 

(Device 

Manager)  Go  to 

Ovládací  panely 

(Control  panel)  and  select 

System

  / 

Hardware

  and  run  the 

Správce za

ř

ízení 

(Device  Manager).  The  next  COM  called 

E218  RS485-USB  Adapter

  has

 

appeared 

among 

the 

Ports

In 

Vlastnosti

  

(Properties),  its  setting,  e.g.  data  rate, 
character  format  and/or  flow  control  can 
be  changed.  Caution!!!  The  control 
signals  are  not  transmitted  hence  no 
hardware flow control can be used. 
Pod  volbou  The  port  number  assignment 
(e.g.  COM3,  COM4,)  may  be  changed 
under the 

Up

ř

esnit

 (Specify option). 

 

4.0 

Specification 

4.1 

Parameters  

  USB interface 

USB 2.0 full-speed (12Mb/s)  

  USB connector 

typ A - male 

  RS485 connector,  

RJ45 

  Terminator 

internal 

 150 Ohm 

  Transmission mode 

asynchronous, half-duplex 

  Maximum data rate 

921 600 kbps 

4.2 

Other 

  Supply 

from USB interface 

  Power take-off 

max. 100 mA 

  Length 

2300 mm 

  Weight 

cca 100 g 

  Skladovací teplota 

- 10

o

 to +55 

o

  Working temperature 

+ 0

o

 to +50 

o

  Humidity 

0 – 85% (non-condensing) 

Содержание E218

Страница 1: ...USB RS 485 Communication adapter virtual serial port ELO E218 Operation manual Virtual COM to Fiber Optics through USB IDLE ECHO ON OFF...

Страница 2: ...on 3 3 2 RS 485 Installing 3 3 2 1 VW3A8E214 version 4 3 3 Installing driver 4 3 3 1 Installing virtual port under Windows XP 4 3 3 2 Uninstalling virtual port under Windows XP 5 3 3 3 Virtual port pr...

Страница 3: ...ate decreases due to the line length and or its impedance growth Recommended maximum line length is 1200 m at the rate of 9600 bps 2 0 Operation principles The adapter E218 converts the RS 485 interfa...

Страница 4: ...apter Following part of the user manual describes the process of installing under MS Windows XP only 3 3 1 Installing virtual port under Windows XP 1 When the PC turned on and the adapter connected to...

Страница 5: ...0 Nalezen nov hardware New hardware found and prepared for use READY indicates that drivers are installed correctly 3 3 2 Uninstalling virtual port under Windows XP Adapter E218 must be connected to P...

Страница 6: ...low control can be changed Caution The control signals are not transmitted hence no hardware flow control can be used Pod volbou The port number assignment e g COM3 COM4 may be changed under the Up es...

Страница 7: ...0 Troubleshooting Symptom Action Adapter does not work after installation Check if the cable is connected properly Check if READY is alight Unplug and plug USB connector Repeat the driver installatio...

Страница 8: ...ELOE218ZK002 8...

Отзывы: