- 85 -
10. TROUBLESHOOTING HINTS
Ref.
Symptom
Checking Point
Page
No image at all
Is the Camera main unit connected correctly with the
P. 7,
on the monitor
monitor with the video cable?
8, 9
Isn’t the MONITOR IN terminal of the monitor wrong?
Isn’t the monitor TV system different from the signal of
this Camera (NTSC)?
Aren’t the video cable damaged?
Aren’t broken or contacted incompletely?
Dark image on
Isn’t the lens iris in the appropriate position? Isn’t the
P. 26,
the monitor
brightness level of the iris low?
50
Isn’t the zoom on the TELE side and imaging a dark,
P. 12,
monochromatic object?
45
Is the high-speed shutter set?
P. 45
No switching to This camera has the Black/White switching function.
P. 44
B&W image
Check the setting.
Shimmer when
Is [HS-SHUTTER] of AE Settings (high-speed shutter)
P. 45
imaging fluore-
set to 1/100s?
scent lamp
The network
Recheck the Camera and the network configuration of
P. 32
function does
the PC connected to it, and check them for the
not work.
phenomena described below.
Recheck the restraints on the Camera, including the
number of connections, and the settings as well.
The operation
• The network operates only in the environment shown P. 20
of the network
below when it is connected to the Web:
is unstable.
1. The OS is Microsoft Windows 2000 or XP.
2. JRE 1.5.0 or a later version is installed.
3. Java (Sun) is enabled.
“ELMO 1Channel Viewer” operates only in the
environment shown below.
1. The OS is Microsoft Windows 2000 or XP.
2. DirectX 9.0C or a later version is installed.