Note:
When connecting several drives to several motors, all should be wired in the same
motor phases and feedback sequences. This will enable the same
SimplIQ
program to run on all
drives.
3.4.1.
Connecting Motor Power
Connect the M1, M2, M3 and PE pins on the Solo Guitar. The phase connection is arbitrary as
the Composer will establish the proper commutation automatically during setup. However, if
you plan to copy the setup to other drives, then the phase order on all copy drives must be the
same.
Figure 5: AC Motor Power Connection Diagram