TECHNICAL MANUAL -
1OASBOX
5. ADJUSTMENT OF RELAY OUTPUT OPERATING MODE
Steps to adjust the output relay function in order to set automatic activation in case of power failure:
- open module housing: carefully open the side fixing clips;
- cut the coloured jumper wire on the left side of the microprocessor;
- when finished, close the module housing by closing the side fixing clips.
Please pay attention not to damage the fixing clips when opening the module:
6. FLUSH-MOUNT DIAGRAM
GENTLY RELEASE
THE BASE FIXING
CLIP UNTIL IT
IS FREE FROM
THE COVER HOLDER
2
PULL COVER AND BASE
GENTLY APART
3
4
REPEAT STEP 1 AND 2
ON THE OTHER SIDE
OF THE HOUSING
PULL COVER AND BASE GENTLY APART
JUMPER WIRE
TO CUT
5
GENTLY FIX
THE BASE CLIPS
TO THE
COVER HOLDER
CAREFULLY
PULL BASE AND COVER
BACK TOGETHER
6
7
503 FLUSH-MOUNT BOX
503 FLUSH-MOUNT
BOX COVER