11
Assembly options
610.44495.40.310 · 09.2013
58
/
60
© Gardner Denver Deutschland GmbH
Assembly of the integrated frequency inverter - 2FC4...-1NE
▪
Mount the buffer (635), if provided, on the adapter plate (648).
▪
Place the gasket (641) on the terminal box opening of the motor housing (001).
▪
Place the adapter plate (648) on the gasket (641) with an overhang on the ven-
tilation side.
▪
Insert the screws (642) into the holes of the adapter plate (648) and screw
them to the terminal box in the motor housing (001).
▪
Position the terminal board (650) on the adapter plate (648).
▪
Apply
medium strength threadlocker
to the screw (651) and insert through
hole of the terminal board (650).
▪
Screw the terminal board (650) and the adapter plate (648) in using the screw
(651).
▪
Insert the seal (681), if provided, suitably into the recess of the adapter plate
(648).
▪
Position the housing trough (639) on the adapter plate (648) with an overhang
on the ventilation side.
▪
Apply
medium strength threadlocker
to the screws (637 and 638) and insert
through the hole of the housing trough (639).
▪
Screw the housing trough (639) and the adapter plate (648) in using screws
(637 and 638).
M
A
=
3.1 – 3.5 Nm
(2.29 – 2.58 ft lbs)
▪
Wire the electrical connections to the terminal board (650) and the housing
trough (639) according to the marks or the circuit diagram (e.g. cable kit,
earthing).
▪
Position the module carrier (698) on the housing trough (639).
▪
Screw the module carrier (698) and housing trough (639) using screws (699) .
M
A
=
0.8 – 1.1 Nm
(0.60 – 0.81 ft lbs)
▪
Place the module (646) or (647) at an angle and snap it into place in the
bracket of the module carrier (698).
▪
Wire all electrical connections to the module (646) or (647) according to the
marks or the circuit diagram.
▪
Position the frequency inverter (600) on the housing trough (639) with an over-
hang on the ventilation side.
▪
Screw the frequency inverter (600) and the housing trough (639) using screws
(682).
M
A
=
3.1 – 3.5 Nm
(2.29 – 2.58 ft lbs)
Complete the assembly using Testing [
➙
59].
11.6
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
Tel. 071 918 60 60, Mail: [email protected]