10
Disassembly options
610.44495.40.310 · 09.2013
48
/
60
© Gardner Denver Deutschland GmbH
Disassembling the integrated frequency inverter 2FC4...-1NE
▪
Remove the screws (682).
▪
Lift the frequency inverter (600) upwards.
▪
NOTICE! The contact strip of the modules (646 or 647) is not designed for
frequent insertion and removal. The module should be removed only if the
drive controller is faulty or if it being replaced with another module.
▪
Mark the power supply cables if required for assembling.
▪
Disconnect all the electrical connections to the module (646 or 647).
▪
①
Bend the retaining collar of the module carrier (698)
carefully
.
▪
②
Push the module slightly towards the retaining collar.
▪
③
Tilt the module out of the holder.
▪
Remove the screws (699).
▪
Lift the module carrier (698) upwards.
▪
Mark the cables, if required, for assembling.
▪
Disconnect all the electrical connections to the terminal board (650) and hous-
ing trough (639).
▪
Remove the screws (637 and 638).
▪
Remove the housing trough (639) by lifting it up.
▪
Remove the seal (681) if available from the adapter plate (648).
▪
Remove the screw (651).
▪
Remove the terminal board (650) by lifting it up.
▪
Remove the screws (642).
▪
Remove the adapter plate (648).
▪
Remove the seal (641).
▪
Remove the buffer (635) if available from the adapter plate (648).
10.3
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
Tel. 071 918 60 60, Mail: [email protected]