Assembly options
11
© Gardner Denver Deutschland GmbH
55
/
60
09.2013 · 610.44495.40.310
Assembly of flange without silencer
Only 2BH20360-1...M
▪
Put the washers (050) onto the screws (051).
▪
Position the stepped pipe (048/049) and screw it in place using screws (051).
All 2BH20... -1
▪
Insert the protective grid (150) into the flange (034).
▪
Position the flange (034) and fit using the screws (142).
If the G-BH2 is equipped with integrated frequency inverter 2FC4..2-
1ST/PB/CB/SC (A), then continue assembly with Assembly of integrated
frequency inverter 2FC4..2-1ST/PB/CB/SC [
➙
56].
If the G-BH2 is equipped with integrated frequency inverter 2FC4..3-
1ST/PB/CB/SC (A), then continue assembly with Assembly of integrated
frequency inverter 2FC4..3-1ST/PB/CB/SC [
➙
57].
If the G-BH2 is equipped with an integrated frequency inverter (A) , then
continue assembly with Assembly of the integrated frequency inverter -
2FC4...-1NE [
➙
58]
Complete the assembly using Testing [
➙
59].
11.3
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
Tel. 071 918 60 60, Mail: [email protected]