Mounting
5
© Gardner Denver Deutschland GmbH
19
/
32
02.2017 · 610.00181.40.000
Connecting pipelines and hoses
WARNING
Risk of injury due to prohibited system-side loads!
Suddenly ejected conveyed media such as impurities and solid particles or
pressure surges can lead to serious injuries.
1. Dimension pipes and hoses, securing elements, fittings and containers suffi-
ciently and align them to the maximum pressures.
2. Connect the F-CEVF and the system de-energised and flexibly (e.g. using
hoses or compensators).
3. Do not fit pipes, hoses, securing elements, fittings and containers to the F-
CEVF and secure from damage.
4. Protect the F-CEVF from non-permitted pressure levels from the plant (e.g.
pressure limiting valve, pressure switch).
5. After switching off, ensure that no conveyed media can flow through the F-
CEVF (external drive through conveyed media), install a check valve if neces-
sary.
WARNING
Risk of injury due to uncased gas inlet!
Severe injuries to body parts, drawing in of hair.
!
Operating without piping (free suction) is solely permitted under the following
conditions:
Take protection measures on the gas inlet to prevent body parts and hair from
being sucked in.
NOTICE
Pressure loss due to reduced cross section of the pipes and hoses!
As possible, make the cross section of the pipes and hoses the same length
or longer than the connections of the F-CEVF.
!
On delivery, all connection openings are closed with a transport protection.
This prevents foreign objects from entering.
1. Remove the transport protection from the connection openings.
2. Connect the pipe or hose of the system suction line to the gas inlet (item
N1.0, [
ڰ
13]).
3. In the case of F-CEVF with a second gas inlet (item N1.0, [
ڰ
13]), connect the
pipe or hose of the system suction line to the second gas inlet.
5.5