Elmo Rietschle 2BH1002-*AA53 series Скачать руководство пользователя страница 22

Servicing 
 

 

 

610.44431.40.000 

22 / 30 

© Gardner Denver Deutschland GmbH

 

 

 

7.2 Repair/ 

Troubleshooting 

Fault 

Cause 

Remedy 

Carried out by

At least two power supply 
leads interrupted. 

Check fuses, terminals and supply leads and 
close circuit where interrupted. 

Electrician 

No signal at control signal 
inputs A and B. 

Apply control signals, see section 5.2.1, 
"Electrical Connection (Motor)", page 11. 

Electrician 

Motor does 
not start, no 
motor noise. 

No speed reference value 
given. 

Set speed reference value, see section 5.2.1, 
"Electrical Connection (Motor)", page 11. 

Electrician 

Impeller jammed. 

Open pump lid, remove dirt and foreign bodies, 
as described in section 7.1.1, "Cleaning", pa-
ge 20. 

Qualified per-
sonnel 

Impeller damaged. 

Replace impeller. 

Service 

Motor bearing damaged.  Replace "complete casing" (i.e. the unit consist-

ing of casing, stator and two ball bearings). 

Service 

Motor does 
not start, 
humming 
noise. 

Wrong connection of mo-
tor connecting leads. 

Check and, if necessary, correct the connection 
of the motor phases and hall signals to the drive 
electronics, see section 5.2.1, "Electrical Con-
nection (Motor)", page 11. 

Electrician 

Winding short-circuit. 

Have winding checked. 

Electrician 

Motor overload. 

Reduce operating pressure. If necessary, clean 
filter, silencers, and pipes. 

Qualified per-
sonnel 

Power con-
sumption too 
high. 

Impeller jammed. 

See "Motor does not start, humming noise". 

Qualified per-
sonnel 

Leak in the system. 

Seal leak in the system. 

Qualified per-
sonnel 

Wrong direction of rota-
tion. 

Reverse direction of rotation by applying the 
correct signals to the control signal inputs A and 
B see section 5.2.1, "Electrical Connection (Mo-
tor)", page 11. 

Electrician 

Speed reference value 
representing the desired 
speed (n

des

) too low. 

Adjust speed reference value (n

des

) within a 

range of 0...10 V. 

Qualified per-
sonnel 

Temperature of the elec-
tronics too high. 

Provide sufficient heat dissipation and cooling.  Qualified per-

sonnel 

Blower too small. 

Use bigger blower. 

Operator / 
qualified per-
sonnel 

Density of the pumped 
gas unequal 1.23 g/m³ 
(= density of air at 15°C 
[59°F] and 1013 mbar). 

Use bigger blower. 

Operator / 
qualified per-
sonnel 

No vacuum / 
pressure or 
too little vac-
uum / pres-
sure gener-
ated. 

Impeller dirty. 

Clean impeller; 
if worn, have impeller replaced. 

Qualified per-
sonnel / Service

Flow rate too high. 

Increase pipe cross section, clean pipe. 

Qualified per-
sonnel 

Abnormal 
screeching 
noise. 

Ball bearing damaged. 

Replace "complete casing" (i.e. the unit consist-
ing of casing, stator and two ball bearings). 

Service 

Impeller leak.  Relative pressure be-

tween blower and sur-
roundings too high. 

The permissible differential pressure between 
the pump interior and the surroundings has 
been exceeded. Make sure that the differential 
pressure is not exceeded. 

Qualified per-
sonnel 

Current feed 
to the mains. 

Caused by switching off 
or rapidly reducing the 
speed of the blower. 

Insert a diode (Schottky diode, size 6A respec-
tively10A) in the 24V respectively 48V supply 
lead (+V

CC

). 

Electrician 

 

Содержание 2BH1002-*AA53 series

Страница 1: ...G Serie G Series Seitenkanal Side Channel Edition 04 2010 610 44431 40 000 Original Operating Instructions English Operating Instructions G BH10 2BH10 02 AB32 2BH10 02 AB22 2BH10 02 AA53...

Страница 2: ...Contents 1 Safety and Residual Risks 3 2 Intended Use 5 3 Technical Data 6 3 1 Nominal and Limiting Values Pump 6 3 2 Nominal and Limiting Values Motor and Electronics 7 4 Transport and Handling 9 5 I...

Страница 3: ...lete standstill Consider impeller run out Operation of the G BH100 only with the pipes hoses connected to the suction and delivery branches WARNING In case of operation with open suc tion or delivery...

Страница 4: ...mbs Drawing in and entanglement of hair Protective measures Operation only with the pipes hoses connected to the suction and delivery branches In case of operation with open suction or delivery branch...

Страница 5: ...tronics 2BH1002 1 flange connection are intended for industrial applications are designed for continuous operation in case of increased turn on frequency or increased intake and ambient temperature th...

Страница 6: ...ating point of ap prox 2 3 of the permissible total differential pressure with the pipes hoses connected and without vacuum or pressure limiting valve 3 Permitted only with unobstructed cooling an ope...

Страница 7: ...l resistance at desired speed 70 Permissible ambient temperature 10 40 C 14 104 F Relative humidity max 95 Due to the PWM control of the electronics the power supply unit is loaded with short high cur...

Страница 8: ...B1 B2 C D d1 d2 E F G G1 K R2 2BH1002 0AB32 145 133 121 95 72 20 19 53 72 11 1 450 4 2 2BH1002 0AB22 145 133 121 95 72 20 19 53 72 11 1 450 4 2 2BH1002 0AA53 145 133 121 95 72 20 19 53 92 11 1 450 4 2...

Страница 9: ...ou can read the conversion factor then Multiply the established conversion factor with the max permissible total differential pressure at 15 C as given in the table in section 3 1 Nominal and Limiting...

Страница 10: ...No direct in solation CAUTION Lay the electrical connecting cable so that it might not be damaged by outer influences and is free from tensile stress Sound and vibration attenuation In order to reduc...

Страница 11: ...PORTANT The motor of the G BH100 including its connecting leads must be pro tected against electrostatic discharge ESD Do not remove the ESD prevention bag surrounding the lead ends until right before...

Страница 12: ...principle external electronics commercial component Colours of the connecting leads of the motor L1 brown RLG1 green GndHall black L2 violet RLG2 white VHall red L3 yellow RLG3 grey Supply voltage co...

Страница 13: ...0 Output stage disabled no current 0 1 Counter clockwise rotation according to the arrow indicating the direction of rotation on the pump lid Main operating direction of rotation of the G BH100 1 0 C...

Страница 14: ...SD Do not remove the ESD prevention bag surrounding the lead ends until right before carrying out the electri cal connection attaching the con nector connecting to a terminal strip or the like Carry o...

Страница 15: ...pation and cooling On delivery the integrated electronics type G BH100 is not equipped with a connector at the connecting cable In this instance the operator can according to the requirements of the s...

Страница 16: ...V DC max 30 V DC grey grey not connected brown not connected red In order to meet the requirements bearing on electromagnetic compatibility an EMI filter from Messrs CORCOM Type 6ETI F7003 6A must be...

Страница 17: ...uction branch and are expelled via the delivery branch The suction branch see Fig 4 4 page 10 is indicated by an arrow pointing into the pump Connect the suction pipe to this branch The delivery branc...

Страница 18: ...tions for tightness check fasteners for secure fixing Proceed as follows Make sure that the suction and delivery pipes are cor rectly connected that in case of operation with open suction or delivery...

Страница 19: ...i IMPORTANT The G BH100 must not be operated with the suction or delivery branches sealed up or jammed CAUTION Burning and scalding hazard due to hot surfaces of the G BH100 Do not touch during opera...

Страница 20: ...check if all fasteners have been re assembled and tightened check pipes hoses and vessels for sufficient strength check pipe hose connections for tightness WARNING Work on electrical installations ma...

Страница 21: ...uts used as given in ISO 898 Cable entry Tighten screwed cable glands Fastening torques on casing side Tf 3 2 Nm 0 2 on cable side Tf 1 5 Nm 0 2 Suction and delivery branches Check pipe hose connectio...

Страница 22: ...nnel Leak in the system Seal leak in the system Qualified per sonnel Wrong direction of rota tion Reverse direction of rotation by applying the correct signals to the control signal inputs A and B see...

Страница 23: ...ith an ESD prevention bag Ensure the correct storage conditions see below Storage conditions Ambient temperature 20 C 70 C 4 F 158 F Relative humidity 10 95 Atmospheric pressure 500 hPa 1 100 hPa Vibr...

Страница 24: ...the Council of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibil ity and repealing Directive 89 336 EEC 2006 42 EC Directive 2006 42 EC of...

Страница 25: ...Gardner Denver Deutschland GmbH 25 30 610 44431 40 000...

Страница 26: ...610 44431 40 000 26 30 Gardner Denver Deutschland GmbH...

Страница 27: ...Gardner Denver Deutschland GmbH 27 30 610 44431 40 000...

Страница 28: ...610 44431 40 000 28 30 Gardner Denver Deutschland GmbH...

Страница 29: ...Gardner Denver Deutschland GmbH 29 30 610 44431 40 000...

Страница 30: ...ations www gd elmorietschle de er de gardnerdenver com Gardner Denver Schopfheim GmbH Roggenbachstra e 58 79650 Schopfheim Deutschland Tel 49 7622 392 0 Fax 49 7622 392 300 Gardner Denver Deutschland...

Отзывы: