background image

5

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

This manual contains important instructions for the Elmec Inc. EVC30T/EVC30T-IN EV Charging Station

 

that should be followed during installation, operation and maintenance of the unit. 

CAUTION

•  To reduce the risk of fire, connect only to a circuit provided 

with 40 amperes maximum branch circuit over current 

protection in accordance with the National Electrical Code, 

ANSI/NFPA 70 and C.E.C Part 1 C22.1-12. 

•  This equipment should be used with an electrically interlocked ventilating 

means during indoor charging of vehicles requiring ventilation during charging. 

 

Verify that:

 

 

1) The ventilating means is operating properly.

 

  2) The ventilation path is free of obstructions.  

•  Do not alter AC cord or plug provided. – Where it does not fit the outlet, have proper

 

outlet installed by a qualified electrician. Improper connection increases the risk of an electric shock. 

Содержание EVC30T

Страница 1: ...User Manual ELECTRICAL VEHICLE CHARGING STATION LEVEL 2 EVC30T EVC30T IN ELMEC Inc Rev June 2016...

Страница 2: ...ions 5 6 Physical Installations Models 5 and 31 7 Physical Installations Models 4 and 30 8 Electrical Connections 9 Operation Sequence 10 Operating Modes Instantaneous Charging 11 Maintenance and Clea...

Страница 3: ...n UL CSA type 3R 4 4X enclosure 25 7 6 m Output Cable SAE J1772TM 30A Output Current 40A circuit breaker Electrical installation with a NEMA 6 50P 240V plug on input cable Portable model non permanent...

Страница 4: ...TM electric vehicle connector E SAE J1772TM connector s release button F Electric vehicle charging cable WARNING DO NOT REMOVE THE BOLTS THAT HOLD THE ALUMINUM HANDLE ONTO THE ENCLOSURE OF THE CHARGIN...

Страница 5: ...ection models 4 and 30 Output connector SAE J1772TM choice of 3 different cable lengths 15 4 6 m 18 5 5 m 25 7 6 m Operating temperature 40 C to 40 C Storage temperature 40 C to 100 C Weight 4 5 kg 10...

Страница 6: ...current protection in accordance with the National Electrical Code ANSI NFPA 70 and C E C Part 1 C22 1 12 This equipment should be used with an electrically interlocked ventilating means during indoor...

Страница 7: ...to observe this precaution could result in death or severe injury Do not use this product if the Electric Vehicle Charging Cable has any indication of damage Do not use this product if the enclosure...

Страница 8: ...a wall But using our wall mounting kit it is possible to mount the unit temporarily on a wall The Figure 5 1 1 illustrates this mounting kit Figure 5 1 1 Portable unit wall mounting kit The wall moun...

Страница 9: ...fixed type charger and is designed to be fixed permanently on a wall using the mounting kit included with the charging station The Figure 5 2 1 illustrates this mounting kit The wall mounting kit mus...

Страница 10: ...ain electrical panel into the junction box Information Consult a qualified master electrician so he can calculate the required size of the cable coming from the main electrical panel 3 Insert the main...

Страница 11: ...your specific electric vehicle 6 When the charge is finished or when the user wants to terminate the charge simply disconnect the SAE J1772TM connector from the electric vehicle by pressing the relea...

Страница 12: ...ous charging This is the mode by default Simply plug the SAE J1772TM connector into the electric vehicle inlet The Main LED will turn to BLUE and the charge will begin for as long as the vehicle stays...

Страница 13: ...s or excessive wear to the charging station itself or to any of the power cords plugs connectors The portable version of the charging station models 5 and 31 must be stored in a clean and dry location...

Страница 14: ...tandard version or switch the dedicated circuit breaker at OFF and then at the ON position Optional version If even after a reset the unit is still in fault mode call the manufacturer support service...

Страница 15: ...al components are accessible The cover is sealed with the rear plate by using rivets and sealant How to get service To use this warranty you must contact the Elmec Inc Support Service and a qualified...

Страница 16: ...vice Support 1141 2e avenue Grand M re Qu bec G9T 2X9 Website elmec ca Email jeanmarc pittet elmec qc ca samuel pittet elmec qc ca Service Support Office 1 819 533 3888 Mobile 24 7 1 819 531 0819 call...

Отзывы: