9
Connection Table
Description
Cable from the main
electrical panel
Cable from
charging station
L1
Black
Black
L2
Red
White
Neutral
White
N/A
Ground
(Bare copper wire)
Green
ELECTRICAL CONNECTION
Models 5 and 31
(with NEMA 6-50P power input connector)
1. Simply connect the NEMA 6-50P connector into a suitable
240V/40A receptacle.
2. Once the unit is receiving power, the Main LED will light up
G R E E N
.
Models 4 and 30
(using a nearby installed junction box)
1. Install a junction box close to the location where you want to install the
charging station permanently.
2. Insert the cable coming for the main electrical panel into the junction box.
Information: Consult a qualified master electrician so he can calculate
the required size of the cable coming from the main electrical panel.
3. Insert the main input cable coming from the charging station into
the junction box.
4. Do the following connections:
This Electrical Vehicle Charging Station
requires a dedicated 40A in the main
electrical panel.
This equipment should be installed, adjusted, and serviced by qualified
electrical personnel familiar with the construction and operation of this type of
equipment and the hazards involved. Failure to observe this precaution could result
in death or severe injury.
5. Re-engage the circuit breaker in the main electrical panel and verify that
the charging station is powered up – the Main LED is
G R E E N
.