background image

 

 

Technical Support: 023 9269 6638 

                        

PAK200838_03A  Feb 2019                           ©2019 ELMDENE INTERNATIONAL LTD 

  

 

O

PERATION

 

 

 
The SI500 sounder is used for notification of an alarm condition as generated within an intruder, hold-up 
or other alarm system. In response to commands from the alarm system control panel, the SI500 will 
emit a high intensity sound. 

 

The SI500 will detect any attempt to gain unauthorised access to the sounder by removal of the cover. 
This will generate a tamper signal* which is normally fed back to the alarm control panel.  

 

The SI500 is classified as a self-powered sounder and has an on-board battery which is recharged via the 
external power source. This battery is used to operate the sounder if the external power is removed. 
 
The SI500 is designed to sound when the BL+ (Blocage) input is removed or connected to 0V. 
 

* The SI500 is a Security Grade 2 product 

 loss of ALIM/Hold-off (charging supply) will cause the sounder to self-activate, but a tamper 

signal is not generated. A tamper signal is only generated in the event that the cover is unscrewed/removed. 

 

 
 
 

FUNCTIONAL 

I

NFORMATION

 

 

 

Tamper Circuit 

The SI500 sounder is provided with a tamper output to detect opening of the cover. 
(See figure 2 for details of tamper connections.) 

 

T

IMER  

O

PTIONS 

S

ELECTION

 

 

 

Table 1: Timer Duration Selection Links 

 

 

KEY

 

 

Link FITTED  

        Link NOT FITTED 

Sound Cut-Off Timer  

T2 
T1 

5 sec.* 

 

 

90 sec. 

 

3 min. 

 

15 min.** 

 

*  

This cut-off time option intended for installation purposes only. 

**

 

Factory default setting. 

 

Response to a fault in the primary power supply (ALIM +/-) 

If the primary power supply develops a fault or is deliberately disconnected, the siren is activated for a 
time depending on the setting of the ringing time

 

 
Sound Cut-off Timer 

The SI500 sounder will automatically stop sounding after the time period selected by the Sound Cut-off 
Timer link, Table 1, irrespective of the status of the sound trigger (BL+) input.  The 5s option is provided 
to reduce nuisance noise during testing 

 
 
 

 

 
 

Содержание SI500

Страница 1: ...ics module Compliant with NF EN50131 4 2009 RTC50131 4 2011 Note For security reasons the tamper output of the siren is triggered when the siren detects Removal of ALIM charging supply Removal 0V supp...

Страница 2: ...Hold off charging supply will cause the sounder to self activate but a tamper signal is not generated A tamper signal is only generated in the event that the cover is unscrewed removed FUNCTIONAL INFO...

Страница 3: ...battery lead after ALIM supply is applied HP Speaker connections ALIM Permanent positive hold off supply ALIM Permanent negative hold off supply AP Tamper output return connections to control panel Se...

Страница 4: ...itable mounting position for the SI500 sounder 2 Drill holes as required for fixing the backplate to the wall and for cable entry to the rear of the unit 3 Route cable from control panel through cable...

Страница 5: ...tenance visit 1 Correct operation of sounder from control panel signal 2 Correct operation of cover and rear tampers 3 Remove the ALIM supply from the control panel and check that the internal battery...

Страница 6: ...low Recharge battery DISPOSAL OF PRODUCT AT END OF LIFE This product falls within the scope of EU Directives 2012 19 EU Waste Electrical and Electronic Equipment WEEE and 2013 56 EU Battery At the end...

Страница 7: ...ominally Battery Deep DIscharge Protection 9 5V nominal resulting in de activation of sounder Battery autonomy duration 36h Tamper detection Cover switch Tamper Output Max 2A 30Vdc rated Sound Trigger...

Отзывы: