Technical Support Line +44 (0)23 9269 6638 (Option 3)
PAK200360 Iss 03B Mar 2012
©2012 ELMDENE INTERNATIONAL LTD
F
AULT
F
INDING
Symptom
Fault
Action
Sounder activated in non-
alarm condition and tamper
shows at panel
Cover not closed correctly.
Check cover closed and screws secure.
Rear tamper pin not correct length
Correct rear tamper pin length.
Sounder stops after 5s
Incorrect timer link setting
Set correct timer jumper links.
Cannot SET control panel
(due to sounder tamper)
Tamper output open due to ENG input
still connected to H+
Disconnect ENG from H+ in sounder or set
control panel programmable output low.
Tamper Source (TS) not connected to
H- for single sounder or to Tamper
Return (TR) for cascaded sounders
Refer to connection diagrams for single
and cascaded sounders (Figures 2 and 3).
Total resistance of tamper circuit too
high for multiple sounder installations
Reduce number of cascaded sounders on
one tamper loop.
Cover or Rear tamper switch not
closed.
Check cover and rear tamper switches fully
closed.
D
ISPOSAL OF
P
RODUCT AT
E
ND OF
L
IFE
This product falls within the scope of EU Directives 2002/96/EC Waste Electrical and Electronic Equipment
(WEEE) and 2006/66/CE (Battery). At the end of life, the product must be separated from the domestic
waste stream and disposed via an appropriate approved WEEE disposal route in accordance with all
national and local regulations.
Before disposal of the product, the SAB battery must be removed and disposed separately via an
appropriate approved battery disposal route in accordance with all national and local regulations. Package
used batteries safely for onward transport to your supplier, collection point or disposal facility.
Caution risk of fire or explosion
if bare battery wires are allowed to touch.
See Specification for battery type information. The battery is marked with the crossed out wheelie bin
symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg).
For more information see: www.recyclethis.info
7