background image

 

 

Technical Support: +44(0)23 9269 6638 (option 3) 

 

PAK200567_01B                                   ©2016 ELMDENE INTERNATIONAL LTD  

 

C

OMPLIANCE

 

 

 
This product meets the essential requirements of the following EU Directives: 

Low Voltage: 

2014/35/EU 

EMC: 

 

2014/30/EU 

RoHS2: 

 

2011/65/EU 

WEEE: 

 

2012/19/EU 

 

D

ISPOSAL OF 

P

RODUCT AT 

E

ND OF 

L

IFE

 

 

 

This product falls within the scope of EU Directives 2012/19/EU Waste Electrical and Electronic Equipment 
(WEEE)  and  2013/56/EU  (Battery).  At  the  end  of  life,  the  product  must  be  separated  from  the  domestic 
waste stream and disposed via an appropriate approved WEEE disposal route in accordance with all national 
and local regulations. 

Before disposal of the product, the standby battery must be removed and disposed separately via an 
appropriate approved battery disposal route in accordance with all national and local regulations. Package 
used batteries safely for onward transport to your supplier, collection point or disposal facility. 

See Specification for battery type information. The battery is marked with the crossed out wheelie bin 
symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg).  

For more information see: www.recyclethis.info 

Caution: 

Risk of explosion if battery is replaced by an incorrect type.   

Dispose of used batteries according to the battery manufacturer’s 

instructions and all local and national regulations.  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

The packaging supplied with this product may be recycled. 

 Please dispose of packaging accordingly. 

 

Содержание G240 BMU Series

Страница 1: ...be used across a wide geographical area The highly efficient switch mode design ensures low operating costs while generating less heat The modular construction simplifies maintenance Universal mains...

Страница 2: ...t circuit removed under mains power only Local Indicators MAINS LED Green FAULT LED Yellow Charge LED Orange Status ON OFF OFF NORMAL Battery fully charged ON OFF ON NORMAL Battery charging ON 1s ON 1...

Страница 3: ...vent of a fault condition the Yellow Fault LED will be illuminated The Orange Battery Charging LED will be illuminated when the battery is not fully charged and is charging normally When the battery i...

Страница 4: ...is is normal 9 Verify load is operating correctly 10 Disconnect mains power Signalling Outputs 11 Connect EPS and GEN fault outputs to appropriate inputs of control equipment Standby Battery 12 Connec...

Страница 5: ...n 3 PAK200567_01B 2016 ELMDENE INTERNATIONAL LTD Module Dimensions 128 98 42 4 60 51 19 84 152 12 4 106 13 G2401BMU G2402BMU 157 1 2 8 7 5 128 42 4 1 9 6 0 5 6 5 4 1 3 5 1 4 3 12 G2403BMU G2405BMU Fix...

Страница 6: ...eplacement of the battery If the output of the PSU fails the cause of the failure should be investigated e g short circuit load The fault should be rectified before restoring power to the PSU The fuse...

Страница 7: ...7 Technical Support 44 0 23 9269 6638 option 3 PAK200567_01B 2016 ELMDENE INTERNATIONAL LTD This page has been intentionally left blank...

Страница 8: ...Before disposal of the product the standby battery must be removed and disposed separately via an appropriate approved battery disposal route in accordance with all national and local regulations Pack...

Отзывы: