background image

 

 

Technical Support: +44(0)23 9269 6638 (option 3)             PAK200546-CHUBB_02DC   Feb 2021 

©2021 ELMDENE INTERNATIONAL LTD  

 

D

ISPOSAL OF 

P

RODUCT AT 

E

ND OF 

L

IFE

 

 

 
This product falls within the scope of EU Directives 2012/19/EU Waste Electrical and Electronic Equipment 
(WEEE) and 2013/56/EU(Battery). At the end of life, the product must be separated from the domestic waste 
stream and disposed via an appropriate approved WEEE disposal route in accordance with all national and 
local regulations. 
Before disposal of the product, any batteries must be removed, and disposed separately via an appropriate 
approved battery disposal route in accordance with all national and local regulations. Package used batteries 
safely for onward transport to your supplier, collection point or disposal facility. 
 

Caution:  Risk of fire or explosion  

if bare battery wires are allowed to touch. 

 
See  Specification  for  battery  type  information.  The  battery  is  marked  with  the  crossed  out  wheelie  bin 
symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg).  

For more information see: 

www.recyclethis.info

 

 
 
 
 

The packaging supplied with this product may be recycled. 

 Please dispose of packaging accordingly. 

 

Содержание 20182423N

Страница 1: ...tage dips do not create a false loss of mains alarm Two LEDs assist with quick and easy installation by showing presence of mains correct battery charging or a fault condition Comprehensive protection...

Страница 2: ...ng battery 4 0 Material 1 2mm steel white powder coated Environmental Temperature 10 to 40 C operating 75 RH non condensing 20 to 80 C storage Standby Battery Management Warning risk of explosion if i...

Страница 3: ...FAULT Relay output for mains fail Open if loss of mains GEN FAULT Relay output for General Fault Open in fault condition BATT Connection to standby battery Use cables provided Observe polarity APS FAU...

Страница 4: ...oad Output 8 Loop correctly rated load cable through supplied ferrite 1 turn and attach to terminal block note polarity Fasten with cable ties Fig 2 Position of ferrite 9 Apply mains power Check Green...

Страница 5: ...n LED is ON 16 Disconnect battery Check that Red Fault LED is indicating a fault refer to diagnostic table on page 7 and that the control panel is showing an APS fault 17 Reconnect battery Check there...

Страница 6: ...wall Check that the tamper switch is CLOSED when the lid cover is closed and the retaining screws are fitted OPEN when the retaining screws are removed and the lid cover is open Use fine adjustment s...

Страница 7: ...N Normal Battery fully charged One short flash every second ON Normal Battery charging but not fully charged Flashing 1second On 1 second Off ON Fault Output fuse or battery fuse blown or battery PSU...

Страница 8: ...al of the product any batteries must be removed and disposed separately via an appropriate approved battery disposal route in accordance with all national and local regulations Package used batteries...

Отзывы: