Clamp
– on Adaptor AC Current
Range
Resolution
Accuracy
200A
0.1A
+1.5% of rdg +3dgts
(meter only, Clamp-on
Adaptor accuracy not
included)
2000A
1A
Sensor: Clamp-on Adaptor (Note: not provide)
200A Range Input Sensitivity: 1mV/A
2000A Range Input Sensitivity: 1mV/A
Frequency Range: 50 to 60 Hz
Overload protection: 500V dc or ac rms.
Resistance
(Auto-ranging)
Range
Resolution
Accuracy
200.0
Ω
0.1Ω
+1.2% of rdg + 4 dgts
2.000k
Ω
1
Ω
+1.0% of rdg + 2 dgts
20.00kΩ
10
Ω
+1.2% of rdg + 2 dgts
200.0kΩ
100
Ω
2.000MΩ
1k
Ω
20.00MΩ
10k
Ω
+2.0% of rdg + 3 dgts
Input Protection: 500V dc or 500V ac rms.
Temperature
Range
Resolution
Accuracy
-50oC~+1000oC
1 oC
+3% of rdg +5dgts
-58oF~+1832 oF
1oF
+3% of rdg +8dgts
Sensor: Type K Thermocouple
Overload protection: 500V dc or ac rms.
Diode Test
Test current
Resolution
Accuracy
0.3mA typical
1 mV
+10% of rdg + 5 dgts
Open circuit voltage: 1.5V dc typical
Overload protection: 500V dc or ac rms.
Audible continuity
Audible threshold: Less than100
Ω Test current: <0.3mA