First start-up
© Elma Schmidbauer GmbH
BA_Elmasteam 4
5
_EN_Vers. 01.2019
15
4
First start-up
4.1
Installation and connection conditions
Keep the packaging if possible or dispose of it properly in
accordance with the applicable disposal regulations.
You can also return the packaging (at your expense) to the
manufacturer.
Inspect the Elmasteam steam jet cleaner for possible transport
damage before start-up. In the case of recognisable damage, the
machine must not be connected to the mains power supply.
Contact the carrier and supplier immediately.
Install the machine on a stable, level and dry surface.
The air slits on the rear side of the machine must not be covered.
Only the original wall bracket (accessory) is permitted to be used
for wall mounting.
Condensation not permitted.
The machine is only permitted to be operated:
•
in well ventilated indoor areas
•
up to a height of 2,000 metres above sea level
•
at an ambient temperature of 5
-
40
ºC [41
-
104 ºF] *)
•
at maximum relative humidity of 80% at 31 ºC [87.8 ºF],
decreasing linearly to 50% relative humidity at 40 ºC [104 ºF] *)
•
with mains power supply if the voltage fluctuations are not
greater than 10 % of the rated value
*)
From 5
-
30 ºC [41
-
86 ºF], the machine can be used with air humidity of up to
80%. At temperatures of 31
-
40 ºC [87.8
-
104 ºF], the air humidity must decrease
proportionally to guarantee the operati
onal readiness (e.g. at 35 ºC [95 ºF] = 65%
air humidity, at 40 ºC [104 ºF] = 50% air humidity). The machine must not be
operated at temperatures above 40 ºC [104 ºF].
Connect the Elmasteam steam jet cleaner to a suitable grounded
power outlet. The technical details of the rating plate must match
the available connection conditions, particularly mains voltage and
connected load.
Packaging
Inspection for
transport damage
Installation
conditions
Ambient conditions
Connecting machine
to mains power
supply