background image

0420 Roto-Jet  

9

OPERATION (CONT.)

Open the foot switch storage compartment and remove the foot switch, “O” ring, rubber hose washer 
and the air hose “quick disconnect” fitting.

Position the foot switch hose in the cutout provided before closing compartment lid.

Install the quick disconnect to an air hose capable of withstanding 100 psi (6.89 Bar-Metric).   
The hose should have an inside diameter of 1/2” (13mm). 

Place the rubber hose washer in the water hose connection of the machine.  This is a one time 
operation.  The rubber washer can remain in this connection and does not require removal after use.

Connect a standard garden hose to the 3/4” water hose connection of the machine.  The machine is 
designed for “Municipal” water pressure only, Max 100 psi (6.89 Bar-Metric).  DO NOT connect the 
water connection to a “High Pressure” source.  Water is important to the cleaning process as it flushes 
away deposits cleaned from the tube and helps to lubricate and cool the flexshaft.

Position the “O” ring in the recess of the flexshaft connection manifold.

Prepare the flexshaft by loosening the four (4) set screws located in the brass locking sleeve using 
a 3/32” Allen wrench.  Thread the breakaway or solid square drive into the coupling adapter that 
is swaged on the core of the flexshaft.  Position the brass locking sleeve equally over the coupling 
adapter and the breakaway or solid square drive.  Firmly tighten the four (4) Allen set screws.  (See 
Diagram B page 8)

Insert the square drive into the manifold of the machine.  Rotate the flexshaft by hand to properly seat 
the square drive of the flexshaft into the manifold.  Thread the brass manifold cap onto the manifold of 
the machine and firmly hand tighten.

Attach the chosen cleaning device to the tool coupling swaged to the core of the flexshaft at the 
opposite end from the manifold connection and firmly tighten the device.  Connect the appropriate air 
pressure source to the machine.  For more information see “Air Supply” section.

Turn on the water supply.

Layout the flexshaft as straight as possible.  DO NOT start the machine with the flexshaft in a coiled 
position.

Depress the foot switch.  Move the throttle valve located next to the air supply connection slowly until 
the air motor starts to turn the flexshaft.  Adjust this valve to the desired RPM for the cleaning device 
and flexshaft being used.  At the same time, water will pass through the machine and out the end of 
the flexshaft casing near the cleaning device.  Remove your foot from the foot switch and both the 
water and rotation of the shaft will stop.  Restart the machine and observe the water output from the 
end of the flexshaft casing.  A constant stream of water should be discharged from the casing as the 
core rotates.  If no water is discharged from the flexshaft, check the hose and hose connection for any 
“kinks” that would restrict water flow.  Depress the foot switch again and observe the water flow from 
the end of the flexshaft.  If no water is discharged, discontinue use of the machine and contact an 
Elliott service facility.

Содержание Roto-Jet 0420

Страница 1: ...www elliott tool com Tube Pipe Cleaners Tube Testers Tube Plugs Tube Removal Tube Installation 0420 Roto Jet Cleaning System Operating and Maintenance Instructions...

Страница 2: ......

Страница 3: ...Contents Introduction 4 Safety 5 Operation 7 Operating Position Diagram A 8 Drive Coupling Diagram B 10 Air Supply Requirements 12 Maintenance 13 Technical Data 15 Trouble Shooting Guide 17 Records 2...

Страница 4: ...rchase welcome to our company our products are our ambassadors If this is a repeat purchase you can rest assured that the same value you have received in the past will continue with all of your purcha...

Страница 5: ...y Provide barriers or shields as needed 7 Use the Right Cleaning Device Do not use a cleaning device or attachment to do a job for which it is not recommended Refer to the Elliott E 100 catalog for al...

Страница 6: ...issing contact an Elliott service facility for a replacement 20 Stop the Machine Immediately if the Flexshaft Starts to Coil Flexshaft damage will occur if flexshaft is operated in a coiled position 2...

Страница 7: ...and cleaning attachments Carry the machine to the location where the cleaning will take place Position the machine at a right angle to the tube sheet or cleaning area This will keep the flexshaft at...

Страница 8: ...8 0420 Roto Jet DIAGRAM A Tube Bundle Roto Jet TOP VIEW CORRECT OPERATING POSITION...

Страница 9: ...crews See Diagram B page 8 Insert the square drive into the manifold of the machine Rotate the flexshaft by hand to properly seat the square drive of the flexshaft into the manifold Thread the brass m...

Страница 10: ...mation see Technical section TOOL TIP Measure the length of the tubes being cleaned from the tube sheet to the tube sheet at the opposite end Transfer this measurement to the flexshaft from the END of...

Страница 11: ...r repellant nonskid foot wear Avoid contact with objects other than the tube when the machine is in operation WARNING DO NOT ALLOW THE FLEXSHAFT TO COIL Coiling of the flexshaft could cause binding wi...

Страница 12: ...st prevention The recommended lubricant to be used is a detergent SAE 10 automotive engine oil Excessive moisture in the air line can cause rust formation in the motor and might also cause ice to form...

Страница 13: ...efficient it may become necessary to flush the motor with a cleaning agent to remove the contaminants To flush the motor Move the throttle valve to the off position disconnect the air supply water sup...

Страница 14: ...two part epoxy paint coating that is very durable and should last the life of the machine Use only mild soap and a damp cloth to clean your machine Certain cleaning solvents can be harmful to the pain...

Страница 15: ...Match the prefix numbers to your shafting size See Fig 3 and 4 Wet Shafts Fig 3 Prefix Flexshaft Number Maximum Torque Inch Pounds Newton Meters 0511 xx 16 1 8 0512 xx 105 11 9 0513 xx 210 23 7 0514A...

Страница 16: ...2 3 2 5 2 6 2 8 2 9 0513 xx 2 4 2 8 3 8 4 4 4 7 5 1 5 4 5 9 0514A xx 2 8 4 1 5 3 6 2 6 4 6 7 7 7 8 4 0514 xx N A 6 0 8 4 10 7 12 1 13 4 14 8 15 8 0515 xx N A N A 11 9 15 7 19 0 22 6 25 0 27 3 Above fi...

Страница 17: ...ce longer than 5 000 hours Ser vice Repair Kit 04230 is available Remove machine cover and check the muffler for corrosion or restrictions Machine rotates but no water is flowing from the end of the f...

Страница 18: ...rced through a tube blockage Reduce the rate of feed on the flexshaft and allow cleaning device additional time to clear the blockage See Operation section Flexshaft coils up when cleaning device is i...

Страница 19: ...0420 Roto Jet 19 NOTES...

Страница 20: ...20 0420 Roto Jet ELLIOTT CHART TUBE MEASUREMENTS UNIT NUMBER _____________________________ TUBE I D TUBE LENGTH UNIT NUMBER _____________________________ TUBE I D TUBE LENGTH...

Страница 21: ...0420 Roto Jet 21 ELLIOTT CHART CLEANING SCHEDULES EFFICIENCIES EFFICIENCY BEFORE CLEANING AFTER CLEANING DATE OF CLEANING EFFICIENCY BEFORE CLEANING AFTER CLEANING DATE OF CLEANING...

Страница 22: ...Half Grommet 04121 1 19 Solenoid Valve 04123 1 20 1 8 Male Elbow Swivel 04128 1 21 1 4 Male Elbow Swivel 04129 1 22 3 8 Tubing 15 Long 04131 15 1 23 Connector 04132 1 24 Foot Valve Complete 04134 1 25...

Страница 23: ...0420 Roto Jet 23...

Страница 24: ...of the coupling Note When replacing the motor coupling insure that the square washer has been placed onto the core before inserting the motor coupling 4 Locate the assembly of the core and coupling i...

Страница 25: ......

Страница 26: ......

Страница 27: ...800 332 0447 Fax 1 937 253 9189 www elliott tool com Printed in the USA 07 2013 Elliott Tool Technologies Ltd TM 1 PL 1 Elliott Tool offers a complete line of precision tube tools to meet your needs...

Отзывы: