2 – INSTALLING THE MP120 SYSTEM
2.1 INSTALLATION PROCEDURE
Installing an MP120 system involves the following steps:
1. laying the necessary connecting cables (bus, detectors, power supply, telephone connections, if any): refer to
the following paragraph for their features;
2. fitting the optional items and accessories into the control unit;
3. installing the control unit;
4. installing the keypads;
5. installing the inserters;
6. installing the input and output expansions;
7. installing the detectors and the alarm and signalling devices (not dealt with in this manual);
8. setting the dip-switches (refer to paragraph
2.3.3 INPUT hardware CONFIGURATION
);
9. configuring and testing the system, as described in the programming manual.
This sequence minimizes the time required to commission an MP120 system, while ensuring optimum results.
2.2 FITTING OPTIONAL ITEMS AND ACCESSORIES
WARNING!
The optional items and accessories must always be connected and disconnected when the
control unit is not powered.
To open the control unit, undo the screw placed on the front cover.
The figures below show the control unit when opened, as well as the position of connectors and holes for the pins
on the master card, including the position for the PSTN ILT100 interface.
PS108 Power Supply
1) SV108 voice synthesis card pin holes
2) SV108 voice synthesis card male connectors
3) TTL/RS232 interface card pin hole
4) TTL/RS232 interface card male connector
5) Tamper connector.
6) Voice synthesis microphone housing
7) Loudspeaker housing
8) Dip switch
9) RST pin
10) Electric output configuration jumpers
11) PSTN telephone interface pin holes
7
6
2
9
1
4
3
8
5
10
11
PS515