29/32
MP120
SV108 VOICE SYNTHESIS ILT100 LINE INTERFACE
Rated current absorption at 12V—
Max. 3 mA
Max. current (during transmission)
30 mA
EP100 PARALLEL INPUT EXPANSION MODULE
Rated supply voltage
10V5 ÷ 15V—
Absorption at rated voltage of 12V—
30 mA max. with all N.C. inputs
26 mA max. with all balanced inputs
Type of data exchange
Serial, Elkron protocol
Max. length of the serial line from the control unit
500 m* (cable section: 2x0.75 for power 2x0.22
for data + 2x0.75 cable for connected sensor power
supply)
ES100 INPUT SERIAL EXPANSION MODULE
Operates in select combination with the
UR1Z
serializing modules
Rated supply voltage
10V5 ÷ 15V -
Absorption at rated voltage of 12V-
30 mA, max. eight UR1Z modules connected
Type of data exchange
Serial, Elkron protocol
Max. length of the serial line from the control unit
500 m* (cable section: 2x0.75 for power 2x0.22
for data + 2x0.75 cable for connected sensor power
supply)
Max. number of expansions that can be connected to
the MP120 system
4 (for 8 UR1Z modules each + 1 24-h input + 1 for aux.
input)
DK2000M INSERTER
Rated supply voltage
12V- (drawn from the master card - serial line)
Absorption at rated voltage of 12V-
18 mA
(all areas set to OFF)
30 mA max.
(all areas set to ON + red LED ON)
Type of data exchange
Serial, Elkron protocol
Max. length of the serial line from the control unit
500 m* (cable section: 2x0.75 for power 2x0.22
for data)
Max. number of inserters that can be connected to the
MP120 system
4
Max. number of programmable DK20 keys
16, individually identified with designation
Max. number of random codes that can be programmed
by the control unit
> 4 billion
Working temperature
-25 °C ÷ +55 °C
*
The maximum distance reached depends to a large extent on the serial line power cable (+ and –) section as
well as the
absorption
found
at the opposite end
. With regard to this, it should be reminded that each
200 m
length of a 2x0.75 mm² cable with
absorption of 100 mA
will cause a drop of approximately
1V
.