6.0 BEAM FREQUENCY CHANGE
- Set Transmitter and Receiver at the same channel.
- Refer to the figures and set the beam channel when two or more units are installed in stacked protection or in
line protection.
- When stacked protection is set up, both the upper and lower sensors should be the same model number
types.
stacked protection
Line protection
Line & 2-stacked protection
7.0 ALIGNMENT AND OPERATION
- Apply power to both Transmitter and Receiver.
- Looking through the view finder, locate the other detector in the center of the sights by adjusting vertically
and horizontally.
- Connect the volt-meter (DC10V) to monitor jack input on Receiver's (+) and (-), then fine turn optical
alignment
- Place attenuation sheet on both transmitter and receiver (lower lens)
- Respectively adjust the optical alignment horizontally & vertically on both transmitter and receiver (upper
side) to obtain the maximum voltage (700mV over) from the monitor jack