13/28 EL50RT 4PH 250m
- WIRING
DISTANCE
WIRE SIZE
12Vdc
24Vdc
0.5 mm
2
160m
1500m
1 mm
2
250m
2200m
1.5 mm
2
530m
4730m
Note:
1. When two or more connections is required,
maximum wiring distance is the value above divided
by the number of sets
2. The power wires could not exceed the above
mentioned lengths.
- CONNECTION SAMPLE
Sample 1
Sample 2
Sample 3
Sample 4
4.0 INSTALLATIONS
The units can be mounted easily on a pole or
flat surface.
- Remove cover via screw at base of cover.
- And loosen the unit base mounting screw and
remove mounting plate by sliding it against the
unit base.
A. Wall mounting
- Pull out the wire through the wiring hole on the mounting plate
and attach the plate to the wall with the screw ( 1/6ªx 3/4ª)
- Connect wire to the terminals.
- After checking optical alignment and operation check, ( please see 7.ALIGNMENT AND OPERATION )
replace the cover, and fasten the cover lock screw tightly.
Power
Alarm (Ch2)
Power
Alarm signal
Control
Panel
Alarm signal
Control
Panel
Power
Power
Alarm
Tamper
Environmental
Signal
Alarm (Ch1)