VERIFY CONTROL BOARD  SOFTWARE

1) To verify the software program of the control board the 

    unit will need to be shut down and restarted. The chiller

    (if present) does not need to be shut down and restarted.

2) The units lower panel must be open to access the power 

    cord and wall outlet.

3) Shut down the unit by unplugging the power cord from the 

    wall outlet. 

4)  Restart the unit by plugging the power cord back into the 

    wall outlet.

5) Upon start up the bottle count display will show the 

    software designation of BF9.

ACCESSING THE PROGRAMMING BUTTON

1)   To access the program button remove the bottom cover of 

     the water cooler. The reset button is located on the left side 

    of the cooler near the cold control. Replace the bottom 

    cover

 

after programming operations are completed.

    NOTE: There is a reset button located under the top cover 

    on the left hand side of the bottle filler also.  

RESET THE FILTER MONITOR

1) Instructions apply to filtered units only.

2) Depress the program button for approximately 2 seconds

    until the display changes then release. The display will

    change and scroll through two messages:

       “RST FLTR” – Reset Filter Monitor

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display

    will scroll through the two messages above for

    three cycles and then default back to bottle count and

     be back in run mode.

3) When the display changes to “RST FLTR”, depress

    the button again. The display will change to show

     “FLT =”. Depress the button again and the display

    will show “FLTR =0”

4) The Green LED should be illuminated indicating that

    the visual filter monitor has been reset.

SETTING UNIT TYPE

1) Depress the program button for approximately 2 seconds

    until the display changes then release. The display will

    change and scroll through two messages:

      “RST FLTR” – Reset Filter Status LED

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display 

    will scroll through the two messages above for 

    three cycles and then default back to bottle count 

      and be back in run mode.

2)  When the display changes to “SETTINGS”, depress

    the button again. The display will change to show

     “RNG SET“-  Range set for IR sensor.

       “UNIT TYP“ - Type of unit (REFRIG or NON-REFRIG)

      “RST BCNT“ - Reset bottle count

3)  When display shows “UNIT TYPE” push program 

    button once the display will show current value

       Can be REFRIG or NON-REFRIG

4) Push button once to change value. Once value is

      selected the display will show the new value.

       (Can be REFRIG or NON-REFRIG)  

     “REFRIG“ - stands for refrigerated product. In this 

     setting the flow rate is estimated at 1.0 gallon per minute.

     “NON-REFRIG“ - stands for non-refrigerated product. 

    In this setting the  flow rate is estimated 

      at 1.5 gallons per minute.

      Both “REFRIG“ and “NON-REFRIG“ simulated 

       1 bottle equal to 20 oz.

5)  Allow approximately 4 seconds to pass and the display

     will return to bottle counter and be in run mode.

    

 RESETTING BOTTLE COUNT

1) Depress the program button for approximately 2 seconds

    until the display changes then release. The display will

    change and scroll through two messages:

      “RST FLTR” – Reset Filter Status LED

      “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display 

    will scroll through the two messages above for 

    three cycles and then default back to bottle count 

     and be back in run mode.

2)  When the display changes to “SETTINGS”, depress

    the button again. The display will change to show

     “RNG SET“-  Range set for IR sensor.

       “UNIT TYP“ - Type of unit (REFRIG or NON-REFRIG)

      “RST BCNT“ - Reset bottle count

    If the button is not pushed again the display will scroll

    through the three messages above for three cycles and

     return to run mode.

3)  When display shows “RST BCNT” push program button

    once the display will show current value e.g. “00033183”.

4) Once display shows current value push the program

    button once more to reset back to 0. The display will

    show BTLCT = 0 for approximately 2 seconds and 

    then return to run mode showing 00000000 bottles.

5)  To test bottle counter:

     REFRIG units:  Push and hold Bottle Filler Button for

     9.4 seconds to see bottle counter count 00000001.

     

(This is based on filling a 20 oz. bottle).

     NON-REFRIG units:  Push and hold Bottle Filler Button for

     6.25 seconds to see bottle counter count 00000001.

     (This is based on filling a 20 oz. bottle)

BF9 PROGRAM

SETTING THE CONTROL BOARD

Содержание LVRCTL8WSC 1A Series

Страница 1: ...Model VRCTL8WS Model VRCTLR8WS VRC8TLWS Series Water Coolers with ezH2O Bottle Filling Stations Refrigeradores de agua serie VRCTL8WS con estaciones de llenado de botellas ezH2O Les refroidisseurs d eau de la série VRCTL8WS avec des stations de remplissage de bouteilles ezH2O INSTALLATION and USE MANUAL ...

Страница 2: ...T INTERRUPTER GFCI LA PUESTA A TIERRA DE EQUIPOS ELÉCTRICOS COMO TELÉFONO ORDENADORES ETC A LAS LÍNEAS DE AGUA ES UN PROCEDIMIENTO COMÚN ESTA PUESTA A TIERRA PUEDE ESTAR EN EL EDIFICIO O PUEDE OCURRIR LEJOS DEL EDIFICIO ESTA PUESTA A TIERRA PUEDE CAUSAR REACCIÓN ELECTRICA EN UNA FUENTE CREANDO UN ELECTRÓLISIS QUE CAUSA UN GUSTO METÁLICO O UN AUMENTO EN EL CONTENIDO METÁLICO DEL AGUA ESTA CONDICIÓN...

Страница 3: ...D autres composants et rugueux dans sont identiques que montrés 20 16 23 1 6 3 37 TL 38 TLR 15 23 27 9 30 FIG 1 LVRCTL8 SHOWN Note Danger Electric shock hazard Disconnect power before servicing unit Nota peligro Peligro de descarga eléctrica Desconecte antes de reparar la unidad Remarque Danger Risque d électrocution Débrancher avant de réparer l appareil 10 22 4 9 30 1 6 6 25a 33 21 36 29 13 25b ...

Страница 4: ...O UN ESPACIO E 6 152 mm MÍN DE HOLGURA ENTRE LA REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED ASSUREZ VOUS UNE BONNE VENTILATION EN GARDANT 6 152 mm MIN ENTRE LES ÉVENTS DE L ENCEINTE ET LE MUR F 7 16 BOLT HOLES FOR FASTENING UNIT TO WALL AGUJEROS DE LAS TUERCAS DE 7 16 PARA SUJETAR LA UNIDAD A LA PARED TROUS D ÉCROUS 7 16 POUR FIXER L APPAREIL AU MUR NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT...

Страница 5: ...N D EAU RECOMMANDE LE TUBE DE CUIVRE DE UNPLATED CONNECTE STUB AVEC ETEINT PAR LES AUTRES 3 dans 76 mm le MAXIMUM HORS DU MUR B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 2 O D DRAIN STUB 2 IN OUT FROM WALL UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA DE 1 1 2 DE DIÁMETRO El TALONARIO 2 FUERA DE PARED EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D E 1 1 2 DE SORTIE D EAU STUB 2 HORS DU MUR C ...

Страница 6: ...o not over tighten screws 6 Secure non refrigerated unit to wall connect drains and water inlet 7 Install the 1 4 poly tubing and insulation from the outlet of the filter to the union on top of the evaporator Install the 1 4 poly tubing and insulation from the regulator in the non refrigerated cooler to one of the tees at the evaporator outlet Install remaining tube insulation to the water line fr...

Страница 7: ...sin when working above it 2 Loosen but DO NOT remove the Pinned Torx Head Screw from the outer side of the Bottle Filler and loosen but DO NOT remove the 1 4 hex head bolt from between the two cooler See Figs 7 or 8 Remove the two 2 Pinned Torx Head Screws from the Top Cover remove the Top Cover The Bottle Filler may then be lifted up and off the Water Cooler The water line will still be connected...

Страница 8: ...p and tighten securely INSTALACIÓN DEL ENFRIADOR DE AGUA 4 Suspenda el enfriador en el fijador de suspensión Asegúrese que el fijador de suspensión calce correctamente en las ranuras de la parte posterior del enfriador como se indica en la figura 2 o 3 5 Afloje los dos 2 tornillos que sostienen la parte inferior del panel en la parte inferior de la base del enfriador y los dos 2 tornillos en la pa...

Страница 9: ...TL8WSC 1A 2A 3A VRCTLR8WSC 1A 2A 3A Page 9 98982C Rev T 01 19 FIG 9 Refrigerated side shown 15 1 13 8 9 1 25a 1 39 TL 40 TLR 15 18 24 35 13 13 32 33 7 7 7 7 5 7 26 30 31 28 7 13 13 7 Items 18 24 also used on the LH unit 1 13 13 30 9 9 15 15 22 ...

Страница 10: ... L VRCTLDDWSC A 2A VRCTLRDDWSC A 2A L VRCTL8WSC 1A 2A 3A VRCTLR8WSC 1A 2A 3A Page 10 98982C Rev T 01 19 Drain Pad Kit 98999C 25b 9 13 1 22 15 FIG 10 Bottle Filler side shown ...

Страница 11: ...idad de refrigeración Refrig Unit Réfrigérateur Stainless Steel Acero inoxidable PANEL COLOR COLOR TABLE COLOR DEL PANEL TABLA DE LOS COLORES TABLE DE COU LEURS COULEUR DU PANNEAU Item No 37 Part No Artículos No No de Pieza Article Pièce Item No 31 Part No Artículos No No de Pieza Article Pièce Item No 32 Part No Artículos No No de Pieza Article Pièce Item No 33 Part No Artículos No No de Pieza Ar...

Страница 12: ...charge Cover 60 Hz Entrée d alimentation Fil assemblée ITEM NO REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY NOTE All correspondence pertaining to any of the above water coolers or orders for repair parts MUST include Model No and Serial No of cooler name and part number of replace ment part REEMPLACE CON EL MISMO COMPRESOR USADO EN EL ENSAMBLADO INICIAL NOTA Toda la correspondencia relac...

Страница 13: ...SINGLE BI LEVEL MICRO SWITCH ACTIVATION DIAGRAMA DE CABLEADO DE 120 VOLTIOS Y 220 VOLTIOS SOLO Y BIPAP MICRO INTERRUPTOR ACTIVACIÓN SCHÉMA DE CÂBLAGE 120 VOLTS 220 VOLT SINGLE VNDP MICRO INTERRUPTEUR D ACTIVATION FIG 15 FIG 16 FIG 17 C OM N O N C MAIN BOARD I R BOARD NOT USED LED BOARD GND SOLENOID RED POWERCORD FOUR PIN CONNECTOR FIVE PIN CONNECTOR WHITE CONNECTOR FROM POWER CORD LINE VOLTAGE SMO...

Страница 14: ...tle count and be back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON REFRIG RST BCNT Reset bottle count 3 When display shows UNIT TYPE push program button once the display will show current value Can be REFRIG or NON REFRIG 4 Push button once to change value Once value i...

Страница 15: ...for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST BCNT Reset bottle count 3 When display shows UNIT TYPE push program button once the display wil...

Страница 16: ...e joint Écrou Rondelle Kit Tee 1 4 Pack de 3 Kit échangeur thermique séchoir Panneau Écran Déshydrateur Ensemble de rechange évaporateur Vis 10 x 1 2 Lg HHSM Tube Drain Pince panneaux avant et arrière Écran VR Kit Le bassin l Acier de Stainless Bassin remplisseur de bouteille en acier inoxyd BF Panneau distributeur inférieur Couvercle de Commande d eau froide Couvercle distributeur inférieur Kit T...

Отзывы: